Kohler K-72218-WB-BL Guía De Instalación Y Cuidado página 20

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Handle Switch Troubleshooting Table
Symptoms
3.
Water does not
fully shut off.
4. Handle LED does
not illuminate
when the handle
is rotated open.
Sensor Troubleshooting Table
Symptoms
1.
Intermittent sensor
operation.
2.
Handle LED is lit,
but power LED is
not.
1318209-2-A
Probable Causes
Recommended Action
A. Refer to the "Handle
A. Valve
setscrew
LED Adjustment"
needs
section.
adjustment.
A. Loose handle
A. Check handle switch
switch wire
wire connection to the
connection.
circuit board.
B. Circuit board
B. Replace the cover
is not
assembly.
functioning
correctly.
Probable Causes
Recommended Action
A. Debris on the
A. Use mild soap and
sensor lens.
water to gently remove
debris from the sensor
lens.
B. Sensor is
B. Rotate the spout away
detecting
from the steam.
steam.
A. Loose sensor
A. Check sensor wire
wire
connection to the circuit
connection.
board.
B. Debris on the
B. At the circuit board,
sensor wire
gently disconnect,
connector.
clean, and reconnect the
sensor wire connector.
C. Circuit board
C. Replace the cover
is not
assembly.
functioning.
20
Kohler Co.

Publicidad

Tabla de contenido
loading

Tabla de contenido