Gas Conversion Operation
This cooking range can be used with LP gas and NG gas. It is shipped from the factory adjusted for use with NG(Nature Gas).
Injector for LP gas are included. Follow the instruction shown below for gas conversion.
WARNING
hotline to identify a factory-trained professional near your home.
WARNING
may result in fire, or electrical shock hazard can occur and result in injury or death. Do not remove regulator or allow it to
turn during servicing.
The gas conversion procedure for this range includes 7 steps:
1. Pressure regulator
2. Cooktop burners
3. Oven burner
4. Broil burner
The conversion is not completed if all 7 steps have not been concluded properly.
Before performing the gas conversion, locate the package containing the replacement injectors shipped with every range.
WARNING
may result in fire, or electrical shock hazard can occur and result in injury or death. Do not remove regulator or allow it to
turn during servicing.
STEP 1: Pressure Regulator
To access the gas regulator, pull the range away from the cabinet wall. The gas regulator is located at the bottom right
corner of the range.
a. Unscrew the cap from the regulator. Do not remove the spring from the regulator.
b. Unscrew the white insert from the cap and turn it over so the longer stem is facing the cap. Replace insert on the cap.
Replace the cap on the regulator.
Gas conversion shall be conducted by a factory- trained professional. Call the customer service
Before carrying out this operation, disconnect the range from gas and electricity. Fail to do so,
Before carrying out this operation, disconnect the range from gas and electricity. Fail to do so,
5. Reconnect Gas and Electrical Supply
6. Installation of new rating label
7. Gas Valve Adjustment (Optional operation)