Assembly - Close-to-Ceiling Mount
1
Preparation for mounting
□
Remove the canopy ring (JJ) from the canopy (C) by turning the
ring counterclockwise until it unlocks.
□
Remove the mounting bracket (A) from the canopy (C) by
loosening the two canopy screws (HH) located in the "L shaped
slots".
□
Remove and save the two canopy screws (II) in the round holes.
This will enable you to remove the mounting bracket (A).
□
Remove the decorative canopy bottom cover (L) from the canopy
(C) by depressing the three studs.
HH
Assembly - Hanging the Fan
4
Attaching the fan to the electrical
box
WARNING: To reduce the risk of fire, electric shock or
personal injury, mount to outlet box marked "acceptable
for fan support of 35lbs. (15.9 kg) or less" and use screws
provided with the outlet box.
□
Pass the 120-Volt supply wires through the center hole in the
mounting bracket (A).
□
Install the ceiling mounting plate on the outlet box by sliding
the mounting bracket (A) over the two screws (NN) provided with
the outlet box. If necessary, use leveling washers (not included)
between the mounting bracket (A) and the outlet box. Note that
the flat side of the mounting bracket (A) is toward the outlet box.
□
Securely tighten the two mounting screws (NN).
2
Routing the wires
□
Remove three of the six screws and lock washers (LL) (every
other one) securing the motor collar (MM) to the top of the
fan-motor housing (D).
□
Place the rubber gasket (EE) over the remaining three screws,
route the wires exiting the top of the fan-motor housing
through the canopy ring (JJ) (make sure the slot opening are
on top), then proceed to place the ceiling canopy (C) over the
collar at the top of the fan-motor housing (D).
□
Align the mounting holes with the holes in the fan-motor
housing (D) and fasten, using the three screws and lock-
washers (LL) removed previously. Tighten the mounting
screws securely.
A
II
C
L
JJ
8
LL
JJ
C
EE
MM
D