Functioning
When the sensing edge detects an obstacle, the automation inverts
the manoeuvre. See parameter settings 73 and 74 on the control
unit.
Check that the wing's operating forces comply with the standards
EN 12453 - EN 12445.
Periodically check the operation of the safety by pressing the
sensing edge during an opening and a closing operation.
12
Reset of the receiver
To delete all the transmitters stored in the receiver:
• Press and hold the P1 button of the receiver until the buzzer
activates a prolonged beep.
• Press and hold the P2 button of the receiver until the buzzer
activates a prolonged beep.
N.B.: delete one channel at a time.
In case of replacement of one or more transmitters, delete ONLY
the corresponding channel to store the new transmitter/s and
proceed to program according to Chapter 10.
13
Error alerts/alarms
Error alert/alarm
Powered receiver
Sensing edge COS1
active.
Sensing edge COS2
active.
Transmitter storage
underway.
Low battery.
Sensing edge
intervention.
Failure to transmit.
14
Disposal
The product may only be uninstalled by qualified technical
personnel, following suitable procedures for removing the
product correctly and safely. This product consists of
numerous different materials. Some of these materials
may be recycled, while others must be disposed of
correctly at the specific recycling or waste management
facilities indicated by local legislation applicable for this category of
product.
Do not dispose of this product as domestic refuse. Observe local
legislation for differentiated refuse collection, or hand the product
over to the vendor when purchasing an equivalent new product.
Local legislation may envisage severe fines for the incorrect disposal
of this product.
Warning! Some parts of this product may contain substances that
are harmful to the environment or dangerous and which may
cause damage to the environment or health risks if disposed of
incorrectly.
8
8
LED
STATUS
LD3 green ON
LD5 green ON
LD4 green ON
LD2 green FLASHING
LD1 red
FLASHING and
Intermittent buzzer
LD1 red
ON
LD4 green OFF
LD5 green OFF
LD1 red
FLASHING
LD4 green FLASHING
LD5 green FLASHING
15
Additional information and
contact details
ROGER TECHNOLOGY is the exclusive proprietor holder of all rights
regarding this publication.
ROGER TECHNOLOGY reserves the right to implement any
modifications without prior notification. Copying, scanning or any
alterations to this document are prohibited without express prior
authorised from by ROGER TECHNOLOGY.
ROGER TECHNOLOGY CUSTOMER SERVICE:
business hours:
Monday to Friday
08:00 to 12:00 - 13:30 to 17:30
Telephone no: +39 041 5937023
E-mail:
service@rogertechnology.it
Skype:
service_ rogertechnology
16
Declaration of Conformity
Herewith, ROGER TECHNOLOGY, via S. Botticelli 8 - 31021 Bonisiolo
di Mogliano Veneto (TV) - ITALY, declares that the devices CS/
STD/RSTX/1600, CS/STD/RSTX/2000 and CS/RX comply with
the essential requirements and other relevant provisions of the
directives:
EN 2006/42/EC;
EN 12978:2003+A1:2009 Cat. 2 PL "d";
EN ISO 13849-1:2008/AC:2009
EN ISO 13849-2:2012
Mogliano Veneto, 2016/05/04
Dino Florian