Instructions For Installation Of Casing Adapter For Single Pipe Jets
1" Drive Pipe
1-1/4" Suction
Pipe
Rubber
Seal
Turned
Coupling
(1-1/4" & 2" size)
Figure 1: Horizontal Casing Adapter with Offset
Installation to Pump
Install Well Casing Components
1. Presoak leather seals on leather packer-type jet by
placing jet assembly in a pail of water for a short
period. If necessary, attach correct jet nozzle to
ejector body, then connect venturi. See instructions
shipped with jet assembly.
2. Connect jet assembly to first length of suction
pipe (see Figure 1). Use 3/4" pipe for 1-1/4" and
1-1/2" casings, 1-1/4" pipe for 2", 2-1/2" and 3"
casings. Use
Teflon™ tape or Teflon™-based thread
1
compound sparingly on male threads only.
3. Lower jet and pipe assembly (suction pipe) into
well casing, adding additional lengths of pipe and
Teflon™ tape until proper depth is reached. Tighten
each joint as lengths are added.
NOTICE: 1-1/4" and 2" casing sizes require special
turned couplings. DO NOT use ordinary pipe
couplings as they restrict water flow and reduce
pump capacity.
4. After correct depth is reached, move suction pipe up
and down a few inches to help seat leathers against
casing. Water pressure will seal leathers more firmly
against casing wall. Allow suction pipe to extend
about 6" above casing. Temporarily support suction
pipe with pipe clamp or other suitable device just
above casing. Check foot valve for leakage by filling
pipe with water. Pipe should remain full.
E. I. DuPont de Demours and Company Corporation, Delaware
1
© 2011
Casing
Adapter
Suction
Pipe
Adapter
Bolt
Pipe
Adapter
Well
Casing
Jet
Assembly
Leathers
Foot
Valve
Figure 2: Horizontal Casing Adapter with Direct
Connection to Pump
NOTICE Numbers shown in parentheses in the following
text, like (2), refer to item numbers shown on Figure 4.
Install Horizontal Casing Adapter
1. Disassemble lower flange (3) from casing adapter (1).
2. Place seal ring (2) over well casing, flush with top
3. Screw casing adapter onto suction pipe. Be careful
4. Remove temporary pipe support clamp and lower
5. Assemble and tighten casing adapter fasteners (5, 8)
Install Vertical Casing Adapter
1. Disassemble lower flange (3) from casing adapter (1).
Rubber
Seal
Turned
Coupling
(1-1/4" & 2" size)
Slide flange over well casing, recessed side up.
of casing.
to start the thread straight. Use Teflon™ tape on
suction pipe thread. A short length of pipe inserted
into larger of two casing holes can be used to tighten
casing adapter onto suction pipe.
casing adapter onto casing. Push suction pipe into
well casing until casing adapter seats evenly over
well casing and as far down as it will go.
evenly until snug to seal adapter to casing.
Slide flange over well casing, recessed side up (see
Figure 3).
Casing
Adapter
Suction
Pipe
Adapter
Bolt
Pipe
Adapter
Well
Casing
Jet
Assembly
Leathers
Foot
Valve
U936 (04/26/2011)

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Pentair U936 LR

  • Página 1 Instructions For Installation Of Casing Adapter For Single Pipe Jets 1" Drive Pipe Casing Adapter Casing Adapter Suction Pipe 1-1/4" Suction Suction Pipe Pipe Rubber Adapter Seal Bolt Adapter Pipe Bolt Adapter Rubber Seal Pipe Adapter Well Turned Casing Coupling (1-1/4"...
  • Página 2 2. Place seal ring (2) over well casing, flush with top of casing. Adapter Pump Gasket 3. Screw casing adapter onto suction pipe. Be careful to start the thread straight. Use Teflon™ tape on suction Casing Adapter pipe thread. Rubber Seal 4.
  • Página 3 Instructions d’installation de l’adaptateur de tubage pour les éjecteurs à tuyau unique Adaptateur Tuyau d’enfoncement de 1 po de tubage Adaptateur de tubage Tuyau d’aspiration Tuyau Tuyau d’aspiration d’aspiration de 1 1/4 po Boulon Joint d’étanchéité d’adaptateur en caoutchouc Boulon Adaptateur d’adaptateur de tuyau...
  • Página 4: Raccordements Déportés De La Pompe

    Placer la bague d’étanchéité (2) sur le tubage à égalité Joint statique de avec le dessus de celui-ci. l’adaptateur de Pompe Visser l’adaptateur de tubage sur le tuyau d’aspiration. tubage Veiller à visser bien droit. Garnir les filets du tuyau Adaptateur de d’aspiration de ruban à...
  • Página 5: Instrucciones Para La Instalación Del Adaptador Del Entubado Para Chorros De Un Tubo

    Instrucciones para la instalación del adaptador del entubado para chorros de un tubo Adaptador del Tubo de hincar de 1" entubado Adaptador del entubado Tubo de aspiración Tubo de Tubo de aspiración aspiración de 1-1/4" Perno del Junta de caucho adaptador Perno del Adaptador...
  • Página 6: Bomba De Acoplamiento Directo

    Coloque la junta anular (2) por encima del entubado del Empaquetadura pozo, al ras con la parte superior del entubado. del adaptador Bomba Atornille el adaptador del entubado al tubo de aspiración. Asegúrese de comenzar la rosca en forma recta. Use cinta de Teflón MC en la rosca del tubo de aspiración.

Este manual también es adecuado para:

U936

Tabla de contenido