Operation
Switching On
EN
The suction unit is switched on and off via the on / off switch (3).
After activation:
♦ The suction unit performs an automatic filter cleaning sequence (for approx. 8 seconds, loud vibrating
noise).
Afterwards, the suction unit is in the last set mode.
Select operating mode: Automatic operation / continuous operation
• Automatic mode (20):
The suction is dependent on the electrical device connected to the appliance outlet (8).
• Permanent operation (22):
Suction running continuously.
⇒ Press operating mode key (21).
♦ Changing the operting mode.
If the suction to a connected electrical appliance (e.g. a handpiece) does not react as required
(e.g. does not activate, even though a connected device is in operation) then the switch-on
threshold for automatic operation must be adjusted.
Suction Power
The suction power for the suction unit can be set in 4 levels.
⇒ [-] key (23):
⇒ [+] key (25):
Setting the Parameter
On delivery, there are parameters set, which in most cases, make it possible to work with the suction unit
without problems. Only in individual cases, if this is not possible, the parameters can be changed.
The setting of various parameters and the execution of a self-diagnosis are carried out in the program-
ming mode.
Please refer to the operating instructions on the Internet or Figs. D and E at the beginning of this
document to find out how to set the parameters and run self-diagnosis.
The display (24) shows which parameter are set:
/
In order to set the different parameters, the programming mode must be started and the parameter select-
ed.
To do so, press the mode key (21) and enter key (27), see Figs. D and E at the
beginning of this document.
Change values with the [-] key and [+] key.
Confirm and save settings with the Enter key (27). Successful saving is acknowl-
edged with an acoustic signal.
If a change is not to be applied, press the mode key (21) again to cancel.
Self Diagnosis (see Fig. D at the beginning of this document)
Start the self diagnosis manually. This is carried out once.
Acoustic signal (see Fig. D at the beginning of this document)
When on, various inputs are confirmed with an acoustic signal. This beep can be switched on and off.
Reduce suction performance
increase suction performance
„d"
Perform self-diagnosis
„b"
Acoustic signal on / off (decimal point on / off)
„A"
Time Interval for "Full" Display Dust Drawer
„c"
Setting the automatic switch-on (calibration)
„t"
Set after-run (time) for the suction turbine
- 4 -