Weller Pyropen WP 60 Instrucciones Para El Manejo página 20

Ocultar thumbs Ver también para Pyropen WP 60:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Ignition Instructions
1. Place gas control lever at the middle and push gas open switch up.
2. Push the knurled nut upward to open ignition holes.
3. Ignite keeping air take-in hole open as illustrated below.
Hold knurled nut until glows the catalyst.
4. Temperature of the soldering tip can be adjusted by moving gas control lever between
left / right.
Sbloccare e rimuovere la punta girando il dado zigrinato e poi montareuna punta a
fiaccola. L'accensione è uguale a quella della punta di saldatura. Accendere nel foro e non
nella parte superiore della punta afiaccola.
The hot exhaust air comes out of the exhaust opening in the tip. Be sure to keep
combustibles, hands, clear from the opening to avoid fire and burns.
Temperature of the hotblow can be adjusted by moving gas control lever from left / right.
To use a hotblow tip
Loosen and remove tip by turning the knurled nut to right and mount a hotblow tip. Ignition is
same as for the soldering tip. Ignite at the ignition hole and not at top of a hotblow tip.
Ignition hole
How to fill butane gas (T005 16 160 99)
Use only high quality butane gas.
1. Check the window for fuel level.
2. Before filling, make sure switch is down.
3. Hold the unit with the refill nozzle upward.
4. Insert nozzle of the butane gas container into the
refill nozzle and press down. Gas will overflow
when tank is full.
18
Gas open lever
Gas control lever

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pyropen wp 60 k

Tabla de contenido