function): the display returns to normal functioning mode displaying the complete
day, month, year date and the partial count at zero once.
Should you be inside the parameters modification menu, the same button
increases the current value.
Select/SET BUTTON
Select the menu parameter to be modified: the top line on the display shows the
selected parameter while the middle line shows the current value. The parameter
displayed can be increased by using the CLEAR/UP button; the new setting can
be confirmed by using the SELECT/SET button.
On entering the menu (the words "ZERO CNT OR MENU" appear on the display),
pressing the SELECT/SET button causes a circular routine to present the follow-
ing parameters in this same order:
YEAR: modification of the year
MON: modification of the month
DAY: modification of the day
HOUR: modification of the hour
MIN: modification of the minutes
SEC: modification of the seconds
TOT: displays the total quantity of precipitation
On further activating the SELECT/SET button the normal functioning mode
returns.
When one of the items is displayed by pressing the CLEAR/UP button its value
can be increased.
To confirm the new setting press the SELECT/SET button.
The detailed description of the steps necessary for the modification of the min-
utes are outlined as an example below.
To enter the menu from the normal measurement condition press the CLEAR/UP
button for three seconds. When the display shows "ZERO CNT OR MENU", press
the SELECT/SET button five times until the current minutes are displayed (YEAR
>> MON >> DAY >> HOUR >> MIN). Using the CLEAR/UP button means the
displayed minutes can be increased up to the new value. This can be confirmed
using the SELECT/SET button.

Battery replacement

HD2013-D is powered by a 3.6V type 1⁄2AA Lithium battery with axial rheophores.
The battery's charge status is constantly monitored and shown on the HD2013
display. When the symbol begins to blink it means the charge level is no longer
sufficient to power the instrument and the battery needs replacing.
Proceed as follows:
1. Download the data and disconnect the instrument from the PC;
2. Unscrew the four screws on the front cover;
3. Release the battery from the ring fastening it to the printed circuit and take it
out of its housing;
4. Cut the rheophores of the new battery to a length of about 15 mm.
5. Put the new battery in making sure the polarity is correct as outlined in fig. 5
6. Fasten it with the elastic ring and close the cover with the screws.
View of tipping bucket
Connection to the PC
HD2013-D can be connected to a PC with a Windows operating system via
serial cable or by using a cable connected directly to the instrument's internal
terminal block; the data contained in the datalogger memory can be discharged
by using the DeltaLog6 software and the data can be displayed in graphic or
tabular form.
The connector located at the base of the instrument is used with the supplied
serial cable.
The internal terminal block can only be used if a longer serial cable is ordered.
Note that in this case the cable length cannot exceed 15 metres. The connection
is outlined in the following table:
HD2013-D terminal block
1 - TX
2 - TX
3 - RTS
4 - CTS
5 - GND

Technical characteristics

Power
Replaceable 3.6V type 1⁄2AA Lithium battery
Type of event recorded
NC or NO contact that the program is able to
select.
An alarm is generated (it can be disabled) if
the contact remains in an unstable condition for
more than 3 seconds.
Resolution
0.1 - 0.2 - 0.5 mm/bucket
Storage capacity
128000 samples equal to 25600 mm of rain
with a resolution of 0.2 mm/sample
PC interface
Insulated RS232C serial port – 9600 baud
Display indications
Partial rain in millimetres or inches
Total rain in millimetres or inches
Environment temperature °C/°F
Operating temperature range -20°C ... +60°C
Protection degree
IP67
Software supplied
DeltaLog6
HD2013
PLUVIOMÈTRE À AUGET
Introduction
Le modèle HD2013 est un pluviomètre à auget fiable et robuste, entièrement
construit avec matériaux anticorrosion pour garantir une longue durée. Pour
assurer une mesure soigneuse en conditions climatiques à basses températures
ou en cas de précipitations neigeuses aussi, il a été prévue une version avec
réchauffage activé automatiquement à environ +4°C qui empêche le dépôt de la
neige et la formation de glace.
Le pluviomètre est constitué d'une base en métal sur laquelle est positionné
l'auget basculant. La pluie est collectée dans un cône, fixé au cylindre en
aluminium, qui achemine l'eau dans l'auget basculant: rejoint le niveau établi,
l'auget calibré, sous l'action de son propre poids, roule déversant l'eau. En
phase de roulement, le contact du tige, normalement fermé, s'ouvre pendant une
fraction de second, envoyant une impulsion au compteur.
La mesure de la quantité de pluie se base sur le comptage du nombre des
vidanges de l'auget: les contacts du tige, normalement fermés, s'ouvrent
au moment de la rotation entre une section et l'autre de l'auget. Le nombre
d'impulsions peut être relevé et acquis avec un pluviomètre enregistreur
(datalogger) tel que le modèle HD2013-D Delta Ohm ou avec un compteur à
impulsions.
Un filtre démontable pour le nettoyage et l'entretien périodique est inséré dans le
cône d'entrée de l'eau pour empêcher que le trou à l'autre extrémité puisse être
obstrué par feuilles ou autres éléments.
Pour un meilleur écoulement des eaux, le cône collecteur a été traité avec
peinture à base de teflon®.
Le modèle avec réchauffeur HD2013R fonctionne avec une tension de 12Vdc ou
24Vdc continus et absorbe environ 35W; l'habilitation pour le chauffage a lieu à
environ +4°C.
Sur demande, au moment de la commande, il est possible obtenir l'installation,
sur le pluviomètre, de pics dissuasifs anti-oiseaux, avec 8 pics ayant un diamètre
de 3mm, et une hauteur de 60mm.
5
Sub D 9-pole female serial connector
3
2
7
8
5