WIRING
Note: Electrical wiring must be done by a
qualified person(s) in accordance with all
applicable codes and standards. This range
hood must be properly grounded. Turn off
electrical power at service entrance before
wiring.
1. Remove screws and cover from the wiring
box.
2. Feed 6" of power cable through the top
opening of the support frame bracket
(installed on ceiling) and into the wiring
box. Secure cable to the wiring box using
an appropriate connector. Fig. 22.
3. Feed the range hoods power cable
through the lower hole of the wiring box.
Fig. 22.
4. Make electrical connections. Wire white-
to-white, black-to-black and green-to-
green. Fig. 22.
5. Push all wiring inside the wiring box. Re-
install the cover and screws making sure
wires are not pinched.
WIRING
BOX COVER
BLK-BLK
WHT-WHT
GRN-GRN
LINE IN
120 VOLTS-60 HZ
6. Tuck excess power cable in-
side the flue.
7. Extend the upper flue toward
the ceiling and secure with (2)
sheet metal screws. Fig. 23.
FASTEN THE
UPPER FLUE
TO THE
SUPPORT
FRAME
BRACKET
- 12 -
SHEET
METAL
SCREWS
FIG. 23
FIG. 22