Cool Seal™ EZ-Ject™ A/C Leak Sealer Kit
Stops refrigerant leaks in air conditioning and refrigeration
systems. Compatible and miscible with the following refrigerants:
R-11, R-12, R-13, R-14, R-22, R-23, R-123, R-124, R-134A, R-141b,
R-404a, R-407c, R-410a, R-502, R-503, R-507 and R-600.
• Do not connect the injector to a system when it is in a vacuum.
• The system must contain enough refrigerant to operate the
compressor and circulate the Cool Seal in order to seal leaks.
• Wear protective glasses or goggles while working on any
AC&R system.
• NOTE: Prior to injecting Cool Seal into any AC&R system, inspect the
service port(s) and valve cores for damage, and open any
supplemental hand or solenoid valves to allow for injection.
CS-100CS kit contains the following:
/
1
(2)
oz. (14.8 ml) pre-filled, disposable standard EZ-Ject™
2
Cool Seal cartridges
(1)
EZ-50—EZ-Ject injector assembly
(1)
CS-25—8" reusable Cool Seal hose with back-check valve,
normally-closed coupler and 119690 purge fitting
IMPORTANT SAFETY INSTRUCTIONS
The Cool Seal hose must be purged and fully charged with Cool Seal
leak sealer before it is used.
1. Completely unscrew the handle on the EZ-Ject injector assembly and
screw the Cool Seal cartridge (CS-1) onto the injector assembly unit.
2. Holding the cartridge vertically with the small cap on top, remove the cap
and screw the cartridge firmly to the check valve on the hose.
3. Insert the adapter/purge fitting into the low-loss fitting on the hose.
4. Turn the handle to advance the plunger until a small amount of Cool Seal
leak sealer exits the assembly. Remove the adapter/purge fitting. The
hose is now purged, ready for use and will remain full of Cool Seal.
NOTE: If the Cool Seal charge is lost, repeat steps 3 and 4.
5. Connect the low-loss fitting to the low-side service port on the AC&R
system. Do not connect the EZ-Ject injector to a system that
is evacuated.
6. Turn the handle to inject the Cool Seal. See the "Cool Seal Dose" chart
below to determine the recommended dosage.
If excessive resistance is met, the valve core in the service port is
not fully depressed. Check that the low-loss fitting is completely
7. After injection, disconnect the low-loss fitting from the service port and
wipe both clean.
COOL SEAL DOSE
In general, each Cool Seal cartridge can treat AC&R systems up to 2 tons.
Use one cartridge to repair systems using up to 15 oz. (444 ml) of refrigerant.
NOTE: Three full cartridges are recommended for all residential split systems.
Size
Up to 4 tons
4-6 tons
6-12 tons
CAUTION
threaded onto the service port.
Cool Seal Cartridges Required
CS-100CS
2
3
4

Publicidad

loading

Resumen de contenidos para Spectroline Cool Seal

  • Página 1 3. Insert the adapter/purge fitting into the low-loss fitting on the hose. 4. Turn the handle to advance the plunger until a small amount of Cool Seal leak sealer exits the assembly. Remove the adapter/purge fitting. The hose is now purged, ready for use and will remain full of Cool Seal.
  • Página 2: Consignes De Sécurité Importantes

    (2) Cartouches de produit Cool Seal standard préremplies jetables EZ-Ject™ oz ou 14.8 ml (1) Assemblage d’injecteur EZ-50—EZ-Ject (1) Tuyau Cool Seal CS-25 20,3 cm (8 po) équipé d’un clapet de non- retour, d’un coupleur normalement fermé et d’un raccord de purge 119690 CONSIGNES DE SÉCURITÉ IMPORTANTES Le tuyau de produit Cool Seal EZ-Ject doit être purgé...
  • Página 3: Dose De Produit Cool Seal

    Ne raccordez pas l’injecteur de produit Cool Seal à un système qui est sous vide. 6. Faites tourner la poignée pour injecter le produit Cool Seal. Voir le tableau « Dose de produit Cool Seal » ci-dessous pour déterminer le dosage recommandé.
  • Página 4: Instrucciones Importantes De Seguridad

    Sellador en frío antes de usarla. 1. Desenrosque por completo el mango del conjunto de inyector BigEZ- Ject y enrosque el cartucho de Sellador en frío Cool Seal (CS-1) en la unidad del conjunto del inyector.
  • Página 5: Wichtige Sicherheitshinweise

    • Tragen Sie für Arbeiten an Klimaanlagen eine Schutzbrille. • HINWEIS: Untersuchen Sie den Anschluss (s) und die Ventileinsätze auf Schäden, bevor Cool Seal in eine Klimaanlage eingespritzt wird, und öffnen Sie alle zusätzlichen Hand- und Magnetventile. Der CS-100CS-Satz setzt sich wie folgt zusammen: (2) 14.8 ml Vorbefüllte Standard-EZ-Ject™...
  • Página 6 Verbinden Sie die verlustarme Anschlussverschraubung mit dem Niederdruckanschluss der Klimaanlage. Verbinden Sie die Cool Seal- Düse nicht mit einem luftleeren System. 6. Drehen Sie den Handgriff, um Cool Seal einzuspritzen. Die empfohlene Dosis lässt sich den untenstehenden Informationen zur Dosierung entnehmen.
  • Página 7 5/14 AM14009 PRINTED IN U.S.A.

Este manual también es adecuado para:

Cs-100cs