Door opening angle
Drawers can be pulled out fully
at door opening of 145°
Connecting the appliance
Have a technician install and connect the appliance
according to the enclosed Installation Instructions.
Do not remove the transportation protection devices
from the shelves and storage compartments until the
appliance has been installed and aligned.
Always connect the water before the power.
Apart from statutory national regulations, you should
comply with all applicable local electricity and water
companies' codes and requirements.
After installing the appliance, wait at least 6 hours
before switching the appliance on. During
transportation the oil in the compressor may have
flowed into the refrigeration system.
Before switching the appliance on for the first time,
clean the interior of the appliance (see section
"Cleaning the Appliance").
65
⁄
" (1664 mm)
1
2
12
⁄
"
19
32
(320 mm)
⁄
"
19
25
(19.5 mm)
90°
145°
41
⁄
" (1047 mm)
4
85
17
⁄
"
1
8
(435 mm)
⁄
"
19
25
(19.5 mm)
90°
145°
Water connection
WARNING
:
Risk of electric shock and damage to the appliance!
Disconnect the appliance from the power source
before performing any work on the water
connection.
Only a qualified installation technician may connect
the appliance to the water supply in accordance
with plumbing and relevant water utility company
regulations.
Connect the appliance to a drinking water line only:
Minimum pressure: 14.5 psi (1.0 bar)
■
Maximum pressure: 116 psi (8.0 bar)
■
CAUTION
:
If the water pressure is more than 80 psi (5.5 bar), a
pressure limiter valve must be fitted; otherwise
there is a risk of water damage. If the water pressure
is below 14.5 psi (1.0 bar), the ice-maker will not
function.
Contact a plumbing professional if you are
uncertain how to check your water pressure.
en-us
min. 2" (50.8 mm)
46
⁄
" (1215 mm)
5
6
9