DT2000XLP
OWNER'S MANUAL
Thank you for purchasing
the DynaTrap
Insect Trap!
®
This product may be covered by one or more U.S. patents
or pending patent applications. See www.DynaTrap.com/patents
IMPORTANT: READ CAREFULLY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING:
when using electric appliances, basic precautions should
always be followed, including the following:
1. Please read all instructions before using the DynaTrap
Insect Trap and keep for future reference.
®
2. To disconnect, turn all controls to the off ("O") position, then remove plug from outlet.
3. To reduce the risk of injury from moving parts or electric shock, always turn unit off and
disconnect plug before servicing or cleaning.
4. Always unplug before replacing lamp. Replace with same type rated 6-Watt bulbs,
DynaTrap
model 32050.
®
5. Do not position the unit near heat, gas, oil or other flammable materials.
6. Place out of reach from children.
7. To reduce the risk of electrical shock, do not put appliance in water or other liquid.
8. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has
been dropped or damaged, or if it has been dropped into water or other liquid.
9. Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
10. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
11. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
12. Do not clean this product with water spray. Do not place where it can fall into water, or near
flammable materials.
13. Do not touch fan while in motion.
14. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle.
Keep cord away from sharp edges.
15. If using outdoors, use only extension cords with a tag stating, "Suitable for Use with Outdoor
Appliances."
16. Use only extension cords that have plug and receptacles that match the product plug.
Replace or repair damaged cords.
17. Only use attachments recommended or sold by the manufacturer.
18. This appliance is provided with double insulation. Use only identical replacement parts.
See instructions or Servicing of Double-Insulated Appliances.
INSTALLATION & OPERATING INSTRUCTIONS
1. Unpack unit. Save carton for off-season storage (if needed).
Remove cardboard insert from the retaining cage.
2. Place the air damper assembly in the retaining cage with the
crossbar facing up. Align the six damper notches with the
matching notches on the retaining cage.
3. Place the trap on the retaining cage and twist clockwise to
the lock position.
4. If hanging the unit, place it approximately 3 - 6 feet above floor
or ground for optimal catch-rate and easy access for cleaning.
Unit can also be placed on the floor or ground.
5. Flip power switch to "ON" ("I") position. The switch is located
under the upper housing near the light bulbs.
6. For best catch results, leave unit on at all times, except when
cleaning or servicing.
7. Catch rate activity will be higher at night. For best catch results,
place unit away from other competing light sources.
8. It is recommended to place the unit 20 - 40 feet away from where
people will be sitting.
9. This unit is all-weather resistant – designed for outdoor use
including rainy conditions. Intended for household and
commercial, indoor and outdoor use.
10. To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the
other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not
change the plug in any way.
11. SERVICING OF DOUBLE-INSULATED APPLIANCES - In a double-insulated appliance, two systems of
insulation are provided instead of grounding. No grounding means is provided on a double-insulated
appliance, nor should a means for grounding be added to the appliance. Servicing of a double-insulated
appliance requires extreme care and knowledge of the system and should be done only by qualified
service personnel. Replacement parts for a double-insulated appliance must be identical to those parts in
the appliance. The symbol must be identical to those parts in the appliance. A double-insulated appliance
is marked with the words "DOUBLE INSULATION", "DOUBLE-INSULATED" or the symbol:
CLEANING
Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.
1. Remove the retaining cage by holding the trap securely and twisting counterclockwise.
2. Grasp the edge of the crossbar and pull up firmly to remove damper assembly.
3. Dispose of contents and clean any buildup from the inside of the retaining cage with a small brush.
4. Attach the air damper assembly to retaining cage and reattach to trap with a clockwise twist to
the lock position.
5. Clean before off-season storage.
IMPORTANT: DO NOT press or push against the screen windows while cleaning or assembling.
REPLACING BULBS REPLACE WITH DYNATRAP
®
BULBS #32050 (or equivalent T5 Type - 120V/6W UVA Bulbs)
The light bulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced
regularly to ensure optimal UV effectiveness. Even though the bulb's light may be visible to you, it's ability to
attract insects diminishes over time.
1. Turn power switch to "OFF" ("0") position. UNPLUG UNIT (1), and allow bulbs to cool before replacing.
2. Remove screw from clear plastic light socket covers (2).
3. Remove both clear plastic light socket covers.
4. Carefully turn bulb counterclockwise and then pull bulb straight out (3).
5. Locate and insert new bulbs into sockets, carefully turn clockwise, and make sure the prongs of the bulb
are seated properly.
6. Replace clear plastic light socket covers and secure with screw.
HOW THE DYNATRAP
INSECT TRAP WORKS
®
Flying insects are attracted to the unit by the UV
light and CO2 that is generated by the photo-
catalysis between the UV lamps and the special
TiO2 coating. The fan then pulls the insects into
the screened base, trapping them until they
dehydrate and die. The base can be removed,
allowing the contents to be periodically emptied
into the trash. Monitor the insects trapped in the
retaining cage, through the see-through screen,
and empty when compartment becomes full.
TROUBLESHOOTING
Problem:
Possible cause:
Correction:
Bulbs do not illuminate
No electrical power.
1. Check plug, receptacle, and fuse or circuit breaker.
and fan does not spin.
Bulbs illuminate, but fan
Shorted fan.
1. UNPLUG UNIT: Examine fan to see that it is free from
does not spin.
foreign material, dirt or build-up of dead insects.
2. Clean unit as in "CLEANING" section.
Fan spins, but bulbs do
1. Bulbs not seated
1. Check all sockets for proper bulb seating and alignment.
not illuminate.
properly.
2. Replace bulbs if needed following instructions under
2. Burnt out bulbs.
"Replacing Bulb".
LIMITED WARRANTY
DYNAMIC guarantees to the original purchaser that this product is free from defective materials and
workmanship. This warranty is limited to remedy any defective part for a period of one year from date of
original date of purchase. Retain your original receipt as proof of purchase. This warranty does not apply
to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been altered, no warranty is in
force. This warranty does not apply if this unit is purchased outside the United States, excluding Canada
and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential, or any other
damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some
states do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion
may not apply to you. This warranty gives you specific legal rights, and you may also have other rights
that vary from state to state.
REPLACEMENT PARTS
32050
2, 6-Watt UV Replacement Bulbs
To see all replacement and accessory parts available for your DynaTrap, visit www.DynaTrap.com.
FOR HOUSEHOLD AND COMMERCIAL, INDOOR AND OUTDOOR USE
Dynamic Solutions Worldwide, LLC
U.S.A. & Canada
12247 W. Fairview Ave. Milwaukee, WI 53226
1-877-403-TRAP (8727)
customercare@dsw-llc.com | www.DynaTrap.com
Mexico
4002907
Dynatrap Servicios de Mexico S. de R. L. de C.V.
This device complies with Performance Standards
01-800-880-8727 | servicios@dsw-llc.com
for Light-Emitting Products, 21 DFR, Part 1040,
©2019 Dynamic Solutions Worldwide, LLC
Chapter 1, Subchapter J, Radiological health.

Publicidad

loading

Resumen de contenidos para DynaTrap DT2000XLP

  • Página 1 UV effectiveness. Even though the bulb’s light may be visible to you, it’s ability to To see all replacement and accessory parts available for your DynaTrap, visit www.DynaTrap.com. 12. Do not clean this product with water spray. Do not place where it can fall into water, or near attract insects diminishes over time.
  • Página 2 IMPORTANTE: NO presione o apriete la malla de metal de las ventanillas en la jaula de retención cuando se le de limpieza 10. Cuando la unidad esté conectada a un tomacorriente, NO introduzca los dedos u otros objetos Para ver todas las piezas de repuesto y accesorios disponibles para su DynaTrap. visite www.DynaTrap.com. o ensamblaje, ya que se podría fácilmente romper.