MODEL: DT2000XLP
OWNER'S MANUAL
Thank you for purchasing this
ALL-WEATHER
CONSTRUCTION
DYNATRAP
Insect Trap!
®
INDOOR/OUTDOOR
RAIN OR SHINE
This product may be covered by one or more U.S. patents
or pending patent applications. See www.dynatrap.com/patents
IMPORTANT SAFETY INSTRUCTIONS
PERTAINING TO A RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
WARNING
, When using electric appliances, basic precautions should always be followed, including the following:
– To disconnect, turn all controls to the off ("O") position, then remove plug from outlet.
– Unplug from outlet when not in use and before servicing or cleaning.
– To reduce the risk of electrical shock, do not put appliance in water or other liquid.
– This appliance is provided with double insulation. Use only identical replacement parts.
See instructions for Servicing of Double-Insulated Appliances.
– Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
– To Reduce the Risk of Electric Shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified
electrician to install the proper outlet. Do not change the plug in any way.
– For Household Outdoor Use Only.
IMPORTANT SAFETY INSTRUCTIONS
Please read these instructions before using the DYNATRAP
®
Insect Trap and keep for future reference.
1. Always unplug before replacing the lamp. Replace bulb with the same type rated 6 watts. (DynaTrap Part# 32050)
2. Do not position the unit near heat, gas, oil or other flammable materials.
3. To reduce the risk of injury, close supervision is necessary when an appliance is used near children.
4. Do not operate any appliance with a damaged cord or plug, or after the appliance malfunctions or is dropped or damaged in any
manner. Return appliance to the nearest authorized service facility for examination, repair, or electrical or mechanical adjustment.
5. This appliance is provided with double insulation. Use only identical replacement parts. See instructions for Servicing of
Double-Insulated Appliances.
6. Do not contact moving parts.
7. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
8. Do not place or store appliance where it can fall or be pulled into a tub or sink. Do not place where it can fall into water, or near
flammable materials.
9. Do not touch fan while in motion.
10. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle. Keep cord away from heat,
oil, or sharp edges.
11. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
12. Only use attachments recommended or sold by the manufacturer.
INSTRUCTIONS FOR DOUBLE-INSULATED, CORD-CONNECTED APPLIANCES:
In a double-insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided on a
double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing of a double-insulated appliance
requires extreme care and knowledge of the system, and should be done only by a qualified service personnel. Replacement parts for a
double-insulated appliance must be identical to those parts in the appliance. A double-insulated appliance is marked with the words
"DOUBLE INSULATION" or "DOUBLE INSULATED". The symbol (square within a square) may also be marked on the appliance.
SAVE THESE INSTRUCTIONS
INSTALLATION
1. Remove cardboard insert from the retaining cage.
2. Place the air damper assembly in the retaining cage with the crossbar facing up.
Align the six damper notches with the matching notches on the retaining cage.
3. Place the trap on the retaining cage and twist clockwise to the lock position.
4. Save carton for off-season storage (if needed).
5. If hanging the unit, place it approximately 3–6 feet above floor or ground for
optimal catch-rate and easy access for cleaning.
Unit can also be placed on the floor or ground.
6. Plug cord into an outdoor outlet or UL listed extension cord as described
in "IMPORTANT SAFETY INSTRUCTIONS".
7. Turn power switch to "ON" position. The switch is located under the upper
housing near the light bulbs.
8. For best catch results leave unit on at all times, except when cleaning or servicing.
9. Catch rate activity will be higher at night. For best catch results, place unit away
from other competing light sources.
10. It is recommended to place the unit 20 to 40 feet away from where people
will be sitting.
11. This unit is all-weather resistant – designed for outdoor use including rainy conditions.
REPLACING BULBS
Light bulbs life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced after that time has passed in
order to maintain optimal UV effectiveness. Even though the bulb's light may be visible to you, it's ability to attract insects diminishes
over time.
1. Turn power switch to "OFF" position, UNPLUG UNIT, and allow bulbs to cool before replacing.
2. Remove screws from clear plastic light socket covers.
3. Remove both clear plastic covers by squeezing the tabs and pulling downward.
4. Carefully turn bulb counterclockwise and then pull bulb straight out.
5. Locate and insert new bulbs into sockets, carefully turn clockwise, and make sure the prongs of the bulb are seated properly.
Replacement bulbs (6-watt fluorescent bulbs – part no. 32050) can be found at your local retailer or can be ordered directly from
DynaTrap by calling 1-877-403-TRAP (8727) or visiting www.dynatrap.com
6. Replace both clear plastic covers by squeezing the tabs and pushing upward into place.
1
2
CLEANING
Clean the trap at least once a week to prolong life of the unit, insure fire prevention, and provide for more efficient operation.
1. Remove the retaining cage by holding the trap securely and twisting counter clockwise.
2. Grasp the edge of the crossbar and pull up firmly to remove damper assembly.
3. Dispose of contents and clean any build up from the inside of the retaining cage with a small brush.
4. Attach the air damper assembly to retaining cage and reattach to trap with a clockwise twist to the lock position.
IMPORTANT: DO NOT press or push against the screen windows while cleaning or assembling.
HOW THE DYNATRAP
INSECT TRAP WORKS
®
Flying insects are attracted to the unit by
AIR DAMPER ASSEMBLY
the UV light and the CO
that is generated
2
by the photo-catalysis between the UV
lamps and the TiO
coating. The fan pulls
2
CROSSBAR
the insects into the retaining cage,
trapping them until they dehydrate and
ALIGNING
die. The screened base can be removed,
NOTCHES (6)
so you can periodically empty the
contents into the trash. The screen allows
you to see what's trapped in the
compartment, alerting you when the
retaining cage needs to be emptied.
RETAINING CAGE
TROUBLESHOOTING
Problem:
Possible cause:
Bulbs do not illuminate
1. No electrical power
and fan does not spin.
Bulb illuminates, but
1. Shorted fan
fan does not spin.
Fan spins, but bulb
1. Bulb not seated properly
does not illuminate
2. Burnt out bulb
LIMITED WARRANTY
DYNAMIC warranties to the original purchaser that this product is free from defective materials and workman-
ship. This warranty is limited to remedy any defective part for a period of one year from date of original date of
purchase. Retain your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor
to, in our judgment, misuse or abuse. If this unit has been altered, no warranty is in force. This warranty does
not apply if this unit is purchased outside the United States, Canada and Mexico. In no case shall DYNAMIC be
liable for any accidental, punitive, consequential, or any other damages of any kind for breach of this or any
4
3
other warranty, expressed or implied, whatsoever. Some states do not allow limitation on how long an implied
warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific
legal rights, and you may also have other rights that vary from state to state.
PARTS & ACCESSORIES AVAILABLE
PART
DESCRIPTION
32050
6-Watt Replacement Fluorescent Bulbs (2 pieces)
32065P
Damper Flaps
Dynamic Solutions Worldwide, LLC
12247 W. Fairview Ave. Milwaukee, WI 53226
Phone: 414-431-2819
Toll free: 1-877-403-TRAP (8727)
Toll free fax: 877-403-3293
Email: dynatrapinfo@dsw-llc.com
Visit us online at www.dynatrap.com
© Dynamic Solutions Worldwide, LLC
2 UV LAMPS
LOOP FOR HANGING
(OPTIONAL)
ON/OFF
SWITCH
TIO
COATED
POWERFUL
2
SURFACE
YET QUIET FAN
AUTOMATIC
DAMPER
CLOSES WHEN
TURNED OFF
PREVENTING
LIVE INSECTS
FROM ESCAPING
RETAINING
CAGE
Correction:
1. Check plug and receptacle and fuse or circuit breaker.
2. Check to make sure power is switched to the "ON" position.
UNPLUG UNIT: Examine fan to see that it is free from foreign material,
1.
dirt or build-up of dead insects. Clean unit as in "CLEANING" section.
1. Check all sockets for proper bulb seating and alignment.
2. Replace bulb if needed following instructions under "Replacing Bulbs".
24/7
This device complies with Performance Standards
for Light-Emitting Products, 21 DFR, Part 1040,
Chapter 1, Subchapter J, Radiological Health.
A000-003