1.5.1
IMPRES 2 End of Service Life LED Indication
As batteries are used, normal wear reduces available capacity. At the successful completion of
calibration and reconditioning, IMPRES 2 chargers compare IMPRES 2 battery capacity to the battery
Rated Capacity.
When the capacity is at a very low value, the IMPRES 2 battery may be nearing its End of Service.
1.5.2
Initiating Calibration and Recondition Manually
Prerequisites:Ensure that the IMPRES battery is removed from the charger for more than two and a
half minutes.
Procedure:
1 Insert the battery into the charger pocket.
2 Remove the battery from the charger pocket.
3 Reinsert the battery into the charger pocket within 5 seconds.
Calibration and recondition start immediately, beginning with battery discharge indicated by a
steady amber LED status. Calibration and recondition are complete only after a full charge
indicated by a steady green LED status. See
1.5.3
Terminating Calibration and Recondition Manually
Procedure:
1 Remove the battery from the charger pocket.
2 Reinsert the battery into the charger pocket within 5 seconds.
Battery discharge immediately terminates and normal battery charging starts. The LED indicates
charge status.
1.6
Authorized Power Supplies and Batteries
This section list out authorized accessories to be used with your charger.
1.6.1
Motorola Solutions Authorized Batteries
Table 2: Motorola Solutions Authorized Batteries
Single-Unit Charger
PMPN4497_
IMPRES Battery Charging Indicators on page
Battery
PMNN4803_
PMNN4804_
PMNN4805_
Chapter 1: IMPRES Batteries and Chargers
Battery Description
BATT IMPRES2 LIION IP68
BATT IMPRES2 LIION TIA4950 IP68
BATT IMPRES2 LIION TIA4950 IP68
MN006348A01-AB