Commissioning
3.1
Connecting Power
Explosion Hazard
Turn off main power before installing AC connections to the flow meter. Contact with
exposed wiring may lead to fire, electric shock, or serious personal injury.
1. Using a 1/16" Hex key, loosen the flow meter Rear Housing Cover locking setscrew.
2. Unscrew the Rear Housing Cover and remove.
3. Locate power supply connector J8. Use the tables below and the part number of your unit
Power Supply Option Code
S
ZN
ZP
Note
Power Supply Module P/N label is located inside the rear housing cover.
FUH1010 IP65 NEMA 7 Interface Detector Quick Start
Operating Instructions, 06/2014, A5E02428148-AA
DANGER
to determine the correct input power source. (See ID label on right side of housing.)
①
Flow meter Number
②
Sensor Type
③
Relay Type
④
Numeric Display
1010X-6SS2
1010X-6ZNS2
1010X-6ZPS2
⑤
⑥
⑦
Power Supply P/N
Power Supply Option
Language Option
Safety Rating Option (S2=FM/CSA,
S9=ATEX & S10=INMETRO)
User Supplied Power
90-250 VAC Single Phase
9-36 VDC Negative Ground
9-36 VDC Positive Ground
3
17