Capacity
Herd capacity
7 gal
75 horses, 75 beef
27 L
75 horses, 75 beef
Capacidad
Rebaño máx.
7 galones
75 caballos, 75 reses
27 l
75 caballos, 75 reses
Drinking height
Net weight
21.65 inches
59.5 lbs
550 mm
27 kg
Altura para beber
Peso neto
21,65 pulgadas
59,5 libras
550 mm
27 kg
1

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Resumen de contenidos para Tru-Test WaterPro 2

  • Página 1 USER GUIDE Capacity Herd capacity Drinking height Net weight 7 gal 75 horses, 75 beef 21.65 inches 59.5 lbs 27 L 75 horses, 75 beef 550 mm 27 kg Capacidad Rebaño máx. Altura para beber Peso neto 7 galones 75 caballos, 75 reses 21,65 pulgadas 59,5 libras 27 l...
  • Página 2: Tabla De Contenido

    Contents Safety warnings ..................................3 Warranty registration................................. 3 Before you start ..................................4 WaterPro2 measurements ..............................4 Basic concrete slab measurements ............................ 4 Concrete and tank hole alignment ............................ 5 Unpacking the box ..................................5 Recommended parts ................................5 Recommended tools ................................5 Included parts ..................................
  • Página 3: Safety Warnings

    Although the information presented in this product document is believed to be accurate and reliable, no responsibility for inaccuracies can be assumed by Tru-Test Limited. Tru-Test Limited reserves the right at any time to change characteristics or specifications without notice.
  • Página 4: Before You Start

    Before you start Measure out the dimensions of the concrete slab that you will need. Length x Width x Overall Height Length x Width x Overall Height WaterPro2 39.2 x 22.1 x 28.7 inches 996 x 563 x 730 mm WaterPro2 measurements Basic concrete slab measurements...
  • Página 5: Concrete And Tank Hole Alignment

    Concrete and tank hole alignment Check your measurements to ensure that the opening on the bottom of the tank aligns with the thermal earth tube placement in the concrete. The opening on the bottom of the tank is off center. Ensure that the water supply lines are not touching the sides of the thermal earth tube.
  • Página 6: Included Parts

    Included parts Get to know the parts of the WaterPro2 before you install it. Contact us on 800 874 8494 if anything is missing. Images are indicative of shipped part and not shown to scale.
  • Página 7: Installation

    Installation Cross-section of final installation The WaterPro2 is designed to provide reliable fresh water to your livestock all year round. When installing the WaterPro2 pay attention to the following areas: Choose a location where the tank will be sheltered from the elements. •...
  • Página 8: Step 1: Preparing The Site

    Have you turned off the water? Step 1: Preparing the site Choose a location that is easily accessible by livestock and sheltered from the elements. Concrete and tank hole Check the measurements of your WaterPro2 against the size of the concrete slab you need. See alignment on page 5.
  • Página 9: Step 5: Pouring The Concrete Slab

    Step 5: Pouring the concrete slab Before you pour the concrete, check that you are using the correct measurements for your WaterPro2. See Concrete and tank hole alignment on page 5. The thermal earth tube (if using) should be flush with the top of the concrete slab. Do not pour concrete into the thermal earth tube or fill the space with dirt or any other material, as it will prevent warm air below the frost line from circulating around the vertical water supply line, and will cause the water line to freeze.
  • Página 10: Step 8: Checking For Leaks

    Step 8: Checking for leaks If necessary, turn the shut-off valve to the SHUT position. Turn on the water supply. With the panel door still open, check the connection between the ½ inch flex line and the water supply. When you are satisfied that there are no leaks, turn off the water supply. With the panel door still open, pull the insulation tube as far upwards as it can go so that the ½...
  • Página 11: Step 9: Installing An Immersion Heater (Optional)

    Step 9: Installing an immersion heater (optional) Inside the tank, slide the 250 W immersion heater under the float. Feed the electric cord through the access cavity. With the panel door open, plug the immersion heater connector it into the electric service, next to the ½ inch flex line. Step 10: Filling the tank Insert the drain plugs on both sides of the tank.
  • Página 12: Recommendations

    Recommendations Split fence measurements The WaterPro2 can also be used to split two pastures or pens with a fence line separating the drinking area. This allows livestock from both sides of the fence to have access to water. Check that you have enough clearance between the float reservoir lid and fence so that you can remove the lid to get to the valve and float assembly.
  • Página 13: Troubleshooting

    Troubleshooting Symptom Possible cause/s Solution/s to check or action: Water frozen in tank Water frozen in lines or Vertical water supply line is properly insulated. connections. Tank bottom is sealed on concrete. Livestock are drinking from the WaterPro2, if not, drain and refill to recycle fresh water.
  • Página 14: Spare Parts

    Spare parts The parts below are available to order from your local Tru-Test WaterPro2 supplier. Images are indicative of spare part and not shown to scale. Panel door Spare panel door fastener kit Float reservoir lid 832895P 832894P 832892P Excludes hardware and fastener kit...
  • Página 15: Valve And Float

    Valve and float...
  • Página 16: Product Warranty

    This warranty applies only to genuine Tru-Test products manufactured by or for Tru-Test, Inc. The liability of Tru-Test, Inc. under this warranty is excluded to the extent that any defect has been caused or contributed to by: Any accident, contamination, tampering, modification, willful damage, improper storage, improper use or negligent act of, or by omission by, any person other than Tru-Test, Inc.;...
  • Página 17 Índice Advertencias de seguridad ..............................18 Registro de la garantía ................................18 Antes de comenzar ................................. 18 Dimensiones del WaterPro2 ............................18 Dimensiones de una losa de concreto básica ........................18 Alineación del concreto con el agujero del tanque ......................19 Instrucciones de desempacado ...............................
  • Página 18: Advertencias De Seguridad

    Registro de la garantía Envíenos sus datos para poder registrar su producto y mantenerlo informado de cualquier actualización importante. Más información en tru-test.com/livestock-waterer-warranty-registration-form Antes de comenzar Mida las dimensiones de la losa de concreto que necesitará.
  • Página 19: Alineación Del Concreto Con El Agujero Del Tanque

    Alineación del concreto con el agujero del tanque Revise las medidas para garantizar que la apertura en el fondo del tanque se alinea con la ubicación del tubo térmico subterráneo en el concreto. La apertura en el fondo del tanque no está centrada. Asegúrese de que las tuberías de suministro de agua no tocan los lados del tubo térmico subterráneo.
  • Página 20: Partes Incluidas

    Partes incluidas Familiarícese con las partes del WaterPro2 antes de instalarlo. En caso de que falte alguna parte, póngase en contacto con nosotros a través del 800 874 8494. Las imágenes indican solo lo que se incluye y no están a escala.
  • Página 21: Instalación

    Instalación Cortre transversal de la instalación final El WaterPro2 está diseñado para suministrar agua fresca a sus animales de manera confiable durante todo el año. Al instalar el WaterPro2, preste especial atención a las siguientes áreas: Elija una ubicación donde el tanque esté lo más resguardado del clima. •...
  • Página 22: Paso 1: Preparación Del Sitio

    ¿Ha cerrado la llave de paso de agua? Paso 1: Preparación del sitio Elija una ubicación que los animales puedan acceder con facilidad y que cuente con protección del clima. Alineación Revise las dimensiones del WaterPro2 en relación con el tamaño de la losa de concreto que necesita. Consulte del concreto con el agujero del tanque en la página 19.
  • Página 23: Paso 5: Vertido De La Losa De Concreto

    Paso 5: Vertido de la losa de concreto Alineación del Antes de colocar el concreto, compruebe que está usando las medidas correctas de su WaterPro2. Consulte concreto con el agujero del tanque en la página 19. El tubo térmico subterráneo (en caso de que lo esté usando) debe estar nivelado con la parte superior de la losa de concreto.
  • Página 24: Paso 8: Verificación De Fugas

    Paso 8: Verificación de fugas Si es necesario, cierre la llave de la válvula de corte. Abra la llave de paso del suministro de agua. Con la puerta aún abierta, revise la conexión entre la tubería flexible de ½ pulgada y el suministro de agua. Cuando haya comprobado que no existen fugas, cierre la llave de paso de suministro de agua.
  • Página 25: Paso 11: Fijado Del Tanque A La Losa De Concreto

    Paso 11: Fijado del tanque a la losa de concreto Use un taladro para abrir agujeros de ½ pulgada (1,27 cm) en el concreto, usando los pies de montaje en cada esquina del tanque como guía. Inserte los pernos de ancla en cada agujero. Coloque arandelas sobre los pernos, y luego las tuercas. Apriete las tuercas y luego repita en las cuatro esquinas, de forma que el WaterPro2 quede fijo.
  • Página 26: Recomendaciones

    Recomendaciones Uso dividido por una cerca El WaterPro2 puede usarse para dividir dos pastizales o corrales con una cerca que separe el área de suministro de agua. Esto permite que los animales de ambos lados de la cerca puedan acceder al agua. Revise que haya suficiente espacio entre la tapa del depósito del flotador y la cerca, de forma que pueda retirarla y acceder al montaje de válvula y flotador.
  • Página 27: Solución De Problemas

    Solución de problemas Síntoma Posibles causas Soluciones a revisar o medidas que puede tomar: Agua congelada en Agua congelada en las tuberías o La tubería de suministro vertical de agua está debidamente el tanque conexiones. aislada. El fondo del tanque está sellado en el concreto. Los animales están bebiendo del WaterPro2;...
  • Página 28: Piezas De Repuesto

    Piezas de repuesto Las piezas a continuación están disponibles en su distribuidor local Tru-Test de WaterPro2. Las imágenes indican solo las piezas de repuesto disponibles y no están a escala. Puerta del panel Kit de ajuste de la puerta del panel Tapa del depósito del flotador...
  • Página 29: Válvula Y Flotador

    Válvula y flotador...
  • Página 30: Garantía Del Producto

    Las responsabilidades de garantía de Tru-Test, Inc. para Productos de suministro de agua automáticos para animales de crianza fabricados por o para Tru-Test, Inc. están limitadas a los términos en la presente política. Tru-Test, Inc. garantiza que sus productos están libres de defectos en materiales y mano de obra durante los periodos descritos a continuación.
  • Página 31 Notes...