Step 9: Installing an immersion heater (optional)
1
Inside the tank, slide the 250 W immersion heater under the float.
2
Feed the electric cord through the access cavity.
3
With the panel door open, plug the immersion heater connector it into the electric service, next to the ½ inch flex line.
Step 10: Filling the tank
1
Insert the drain plugs on both sides of the tank.
2
Turn on the water supply to fill the tank and check for leaks. If no leaks are found, attach the float reservoir lid.
Step 11: Affixing the tank to the concrete slab
1
Drill ½ inch holes in the concrete using the mounting feet located on each corner of the tank as a guide.
2
Insert anchor bolts in each hole. Place washers over anchor bolts, then apply the nut. Tighten the nut and repeat on all four
corners so that the WaterPro2 is securely mounted.
3
We recommend caulking the perimeter of the tank to protect it from wind and debris.
Pressure and flow capacity
You may need to install a pressure reducer on the vertical water supply line in hilly areas where the water pressure is affected.
PSI
Flow (Gal/min)
14.5
4.0
29
4.8
43.5
5.7
58
6.1
72.5 MAX
7.1
WaterPro2
Flow (L/min)
15.1
18.3
21.5
23
26.8
11