Battery/Rechargeable Battery Operation; Lc Display Of The Power Packs - Sennheiser SKM 5000 Instrucciones Para El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
Battery or rechargeable
battery operation ?
For regular operation you should use non-
polluting rechargeable batteries (BA 5000-1)
instead of batteries.

LC display of the power packs

B 5000-1 battery pack:
3-step LC display for (remaining) battery
capacity
Reliable Low Batt indication
Protection against total discharge
Provision of battery status information for
the receiver
Operating time (with alkaline manganese
cells): B 5000-1: > 4.5 h on SKM 5000
BA 5000-1 accupack:
6-step LC display for (remaining) recharge-
able battery capacity
NiMH rechargeable batteries with 1.5 Ah
capacity
Charging time max. 2.5 h with L 50 charger
(depending on the residual charge of the
rechargeable battery)
Indication of partial discharge via LC display
Protection against total discharge
... Indication at the EM 1046 (Example)
The display of an EM 1046-RX-module
(channel module),too, indicates the residual
operating time in %. The residual operating
time of approx. 30 minutes (see above) is
indicated by the blinking warning signal
LowBatt
Note
You will find a corresponding description
in the instructions for the EM 1046 / EM
3031 / EM 3032 / EM 3532 / EK 3041.
SKM 5000, BDA 06/02
".
15
>
<
Low-Batt
15
04.06.2002, 11:18 Uhr

Publicidad

Tabla de contenido
loading

Tabla de contenido