WIRING (IPP9IQT)
Note: This range hood must be properly
grounded. The unit should be installed by
a qualifi ed electrician in accordance with
all applicable national and local electrical
codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box (Fig.13).
2. Secure the supply wire to the wiring box
through a approved wire connector.
3. Make electrical connections. Connect white
to white, black to black and green to green.
4. Replace wiring box cover and screws.
Make sure that wires are not pinched
between cover and box.
ADDITIONAL EXTERNAL
BLOWER WIRING (IPP9E)
1. Run 2-wire plus ground power cable from
the exterior blower to the hood's wiring box
marked "motor connection" (Fig.14).
2. Remove the cover from the wiring box and
remove one knockout.
3. Feed 6" of cable through the knockout
opening and secure the cable to the wiring
box with an appropriate connector.
4. Make electrical connections at the hood.
Connect white-to-white, red-to-black and
green-to-ground.
5. Replace the wiring box cover and screws.
Make sure wires are not pinched between
the cover and box.
Exterior blower connection:
1. Make electrical connections at the exterior
blower (see instructions provided with the
exterior blower).
Once wiring operations are complete, re-
move tape and slide down the lower fl ue .
CONNECT DECORATIVE FLUE
Attach the upper fl ue to the upper sup-
1.
port frame with the mounting screws
3,9x9,5mm (Fig.15).
2. Lower the lower fl ue in place.
WIRING BOX
BLOWER CONNECTION AT HOOD
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
- 12 -
COVER
EXTERIOR BLOWER
BOX MARKED
CONNECTION"
MOUNTING
SCREWS
3,9x9,5mm
FIG.13
"MOTOR
FIG.14
FIG. 15