ADJUSTING THE SETTINGS WITH THE REMOTE CONTROL (To be orderet separately)
If necessary, the sensor settings can be adjusted as following:
Shut o the water supply. In order to adjust the sensor with the remote control, hold the remote control straight
in front of the sensor in a distance of about 6-8" (15-20cm). Choose the function you want to adjust by pressing
Once on one of the function buttons. After pressing once on a speci c function button, a quick ashing of the red light
at the front of the sensor will occur. at this stage, you can change the setting by pressing the (+) or the (-) buttons,
every push will increase or decrease one level. After nishing the adjustment, turn the water supply back on.
DETECTION RANGE: Only if necessary, use the remote control to adjust the sensor range as follows:
Press the RANGE button. Wait until a quick ashing of the red light of the sensor eye is perceived.
Then, press + to increase the one level and - to reduce it every push will increase or decrease one level.
NOTE: Once you have changed the detection range with the remote control,
this distance will be remembered by the sensor, even if the power source is disconnected.
SECURITY TIME: The Security time, prevents continuous running of water due to re ections
or vandalism. By dafault, if the sensoris covered for more than 10 minutes the water ow will
shut automatically. To resume regular operation any obstruction must be removed.
Press the SEC button. Wait until a quick ashing of the red light of the sensor eye is perceived.
Then, press + to increase the security time and - to reduce it.
DELAY IN TIME: It is recommended to change the delay in time for ush valves for urinals or toilets
valves for urinals or toilets only.
If required, the delay in time can also be modi ed in faucets as follows: Press the IN button. Wait
until a quick ashing of the red light of the sensor eye is perceived. then, press + to increase the
delay in time and - to reduce it.
DELAY OUT TIME: This button allows modifying the water ow time after the user removes his hands
from the faucet. A delay out time close to 0 will save more water. An increased delay out time will make
the user experience more confortable.
If required, the delay out time can be modi ed as follows:
24 HOUR HYGIENE FLUSH: If you have a compatible model with a 24 hours hygiene ush it is possible
to enable and disable it.
To activate the hygiene ush, press the clock button. wait until a quick ushing of the red light of sensor
eye is perceived. Then press + to activate the hygiene ush or - to deactivate it.
TEMPORARY OFF FUNCTION: This function is ideal to perform any kind of activity in front of the sensor
without operating the system (for example, cleaning). The faucet will remain shut for 1 minute when
this button is pressed once.
To cancel this function and to return to normal operation press the On/O button again or wait 1 minute.
RESET BUTTON: This function restores all the factory settings except for the sensor range. If required, press
the Reset button and without releasing it, press the + button once.
DETECTION
DELAY OUT TIME
RANGE
TEMPORARY OFF
DELAY IN TIME
SECURITY TIME
HYGIENE FLUSH
FUNCTION
RESET
13