When the timer has expired, the buzzer starts sounding and the bottom display shows the "End"
message.
To mute the buzzer pus a key: The display come back to show the humidity and the LED of the
START key is turned off.
2.6. HOW TO STOP THE CYCLE MANUALLY
When the cycles are repeated indefinitely as the controller is programmed factory, the drying cycle
stopped manually.
To stop the cycle manually push the ON/OFF key.
2.7. HOW TO MODIFY THE SETTING OF THE CURRENT CYCLE WHILE IT'S RUNNING
To modify the setting of the running cycle temperature (SET_T), humidity (SET_RH) or remaining
time (CLOCK):
a. Push twice the correspondent key: the setting value of the current phase (dripping or running)
will be displayed,
b. Modify it using the UP and DOWN keys,
c. Confirm the value using the correspondent key: temperature (SET_T), humidity (SET_RH) or
remaining time (CLOCK).
NOTE: the changes made will be memorised. So the next cycle will start with the new values.
3. MODIFICATION OF PARAMETERS FOR USE AS REACH-INS
In dripping phase the controller works controlling only temperature, therefore, what we will give the
dripping phase lasting 23 hours to leave the set point temperature and set the duration of the other two
phases to zero.
To do this follows the following procedure:
3.1. SET THE DURATION OF THE DRIPPING PHASE IN 23 HOURS AND THE ON AND OFF
PHASES AT 0 HOURS
a. Push the CLOCK key, the display shows on the bottom display the "dri" message,
while the "hourglass" start flashing,
b. Push again CLOCK the duration of the dipping phase is shown, adjust the time using
the keys UP and DOWN until appear "23:00",
Page: 5 /6
Date: 06/04/16 Review: 01