Descargar Imprimir esta página

nVent RAYCHEM JBM-100-E Manual De Instrucciones página 5

Ocultar thumbs Ver también para JBM-100-E:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
VPL: maximum pipe temperature in
dependence of heat type and voltage
Heater Type 385 Vac
5VPL4-CT
230°C
10VPL4-CT 215°C
15VPL4-CT 195°C
20VPL4-CT 150°C
Specific conditions for use using ATEX or IECEx approvals:
For ambient temperatures >+40°C:
Use a power cable with continuous temperature resistance of minimum +90°C
Use a metallic power cable gland approved for use in hazardous areas
(for example GL-38-M25-METAL).
For voltages >254Vac and BTV, QTVR, XTV, KTV or HTV heating cables:
Use a power cable with continuous temperature resistance of minimum +90°C
Use a metallic power cable gland approved for use in hazardous areas (for example GL-38-
M25-METAL).
For pipe temperature > 150°C and XTV, KTV or HTV heating cables, the maximum operating
current shall be reduced to maximum 20A.
WARNING: To prevent elec tri cal shock, short cir cuit or arc ing, this prod uct must be
in stalled cor rect ly and water ingress must be avoid ed before and during the in stal la tion.
Before installing this product, read the installation instructions completely.
CAUTION: Prolonged or repeated contact with the sealant in the core sealer may cause skin
irritation. Wash hands thoroughly. Overheating or burning the sealant will produce fumes that
may cause polymer fume fever. Avoid contamination of cigarettes or tobacco. Consult MSDS
VEN 0058 for further information.
DEUTSCH
PTB 20 ATEX 1008 U
II 2 G Ex eb mb IIC Gb
II 2 D Ex tb mb IIIC Db
IECEx PTB 20.0014U
Bemessungsspannung:
Umgebungstemperatur:
Schutz gegen Eindringen IP66
(1)
(1)
Ex eb IIC T* Gb
Ex tb IIIC T*°C Db
-L-E(P)
Ex eb mb IIC T* Gb
Ex tb mb IIIC T*°C Db
Bemessungsspannung: 277 V AC
400 Vac 480 Vac
230°C
230°C
215°C
205°C
195°C
160°C
150°C
150°C
nVent RAYCHEM JBM-100-E(P): 480 V AC**
JBM-100-L-E(P): 254 V AC
JBM-100-E(P): –55°C bis +56°C**
JBM-100-L-E(P): –40°C bis +40°C, bei Verwendung mit VPL kann die
Umgebungstemperatur bis zu +56°C betragen.
JBM-100-E(P):
ТС RU C-BE.МЮ62.В.00054/18
Ex e IIC Gb U Ex tb IIIC Db U
Ex e mb IIC Gb U Ex tb mb IIIC Db U
Ta –55°C...+56°C IP66
ООО "ТехИмпорт"
HTV:
HTV-Zulassungen in Vorbereitung
BR-EX e II
BR-Ex em II
VPL: Maximum pipe temperature
in dependence
≤ 150°C
≤ 180°C
30 A
25 A
30 A
25 A
30 A
25 A
30 A
JBM-100-L-E(P):
ТС RU C-BE.МЮ62.В.00054/18
Ex e IIC Gb U Ex tb IIIC Db U
Ex e mb IIC Gb U Ex tb mb IIIC Db U
Ta –55°C...+40°C IP66
ООО "ТехИмпорт"
nVent.com/RAYCHEM | 5
≤ 230°C
20 A
20 A

Publicidad

loading

Este manual también es adecuado para:

Jbm-100-epJbm-100-l-eJbm-100-l-ep