Lavatory Rim
Roughing-In
For K-2432:
IMPORTANT! The rough-in plumbing must extend 3" (7.6 cm)
beyond the finished wall.
Remotely locate the shut-off valves (such as below the vanity)
according to the roughing-in information. Use a 90° shut-off valve
with 3/8" compression outlet.
Install water supply lines according to the roughing-in
information.
For All Models:
Install all electrical supply lines according to the roughing-in
information. A Class A Ground-Fault Circuit-Interrupter (GFCI) or
Earth-Linkage Circuit Breaker (ELCB) must be used.