Menus; Automatic Setting Menu - MURPROTEC CTA Instrucciones De Uso

Central de tratamiento de aire
Ocultar thumbs Ver también para CTA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 52
CTA4-Mode-d-emploi(A5)-2021
2/02/21
18:04
Page 45
Screen
Contrast
Brightness
Basic settings
Back to original settings ?
!!! REPLACE FLOW RATE AND
TEMPERATURE SETTINGS !!!
Cancel
Confirm
Menu reached by pressing
or
when on main screen:
Choose a temporary forced flow rate.
Press BACK to cancel.
Choose duration in hours for a floaw
rate of X %

4. MENUS

To go to the menus, press
.
Use
and
to change menu and
to enter it..
Press
to go back.
Remark: When a menu is idle for some 30 seconds, the system
automatically goes back to the previous screen and so on,
Screen :
until the main screen.

4.1. Automatic setting menu :

The system adjusts automatically the air flow and temperature requested
depending on either the regional weather forecast, if you have a connected
device, or autonomously, if you do not have the connected option. The system
can thus use hot or cold air in the best and most efficient way possible.
The air flow displayed is called the basic air flow.
The temperature displayed is the setpoint temperature.
Screen :
To change the values, go to "Change" and press
Depending on the configuration of your installation, the programme will recommend an air flow and temperature (You are
not required to take them into account).
Set the values wit
and
. Confirm with
.
Settings:
Basic air flow: 10 to 100%
Setpoint temperature: 5 to 18°C
43

Publicidad

Tabla de contenido
loading

Productos relacionados para MURPROTEC CTA

Tabla de contenido