Safety System - Skymsen CSE Manual De Instrucciones

Ocultar thumbs Ver también para CSE:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

if there is a great quantity of the product to be processed. This can be seen if pieces of
the fruit are going out with the juice or when waste stops falling into the bowl collector
or by the Outlet pipe;
8.In this case, turn the machine OFF (even from the electrical network), loose the Fast
Lock and remove the Liquid Chamber Lid;
9.Remove the waste that is obstructing the exit, wash the Liquid Chamber Lid with water,
assemble the Lid back in the machine fixing it by the Fast Lock and continue to process
the products;
10.When processing diferente products, all the parts that were in contact with the
previous product must be removed from the machine, cleaned and reinstalled.

3.3 Safety System

3.3.1 Sensor to monitor the Liquid Chamber Lid
To provide more safety to the users, this Centrifuge Juicers CSE has a sensor that avoids
the machine to be turned ON without the Liquid Chamber Lid on its working position.
This equipment has a security system to guarantee the operator integrity.
The operation of this equipment must be performed as described in the item
"Operation" of this manual. Other procedures to operate this equipment are not
3.3.2 Reset System
For your safety, this equipment has a security system that prevents its involuntary operation
after an eventual electricity failure.
After electricity is reestablished, press the OFF Switch and then press the ON Switch.
Never clean the equipment if connected to the electric network. To do so, unplug
it. Before removing the Liquid Chamber Lid, make sure the motor is completely
10
IMPORTANT
safe and must not be used.
IMPORTANT
stopped.

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido