Installation Method
Connect the external pipelines as follows:
To rejected water outlet
(sewer drainage)
1. Debugging method
1.1 After the installation of the purifier, open the three-way ball valve and turn on the power supply after checking there is no water leakage in the
connections between the purifier and others;
1.2 Turn on the faucet and flush the RO membrane filter; and please follow the following steps so as to achieve the maximum purification effect of
the RO membrane filter:
1) Turn on the faucet to keep normal water purification for 2 hours.
2) Turn off the faucet to leave the purifier standing for 24 hours.
3) Turn on the faucet, the purified water can be drunk directly after 2 hours of normal purification.
Notice:
The device will start self-protection program every 30 minutes' continuous working, at this time, please power off the device by unplug the power
supply, then re-power on the power supply, the device can work normally, if any other problems, please contact your local Pureit dealer.
Power
adapter
(The picture is for reference only, and the real product shall prevail)
Gooseneck faucet
To purified water outlet
To other faucets
Pressure relief valve
To water
inlet
Three-way ball valve
Main inlet valve (cold
water angle valve)
Water-leakage alarm indicator
- 11 -
EN