WaterLink Spin Touch DW 3585 Manual De Usuario página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Other Settings
RANGES
Test Factor
Alkalinity, Total
Chlorine, Free
Chlorine, Total
Combined Chlorine
Copper
Hardness, Total
Iron, Ferrous, soluble
Iron, Ferric, soluble
Iron, Total, soluble
Nitrate
Nitrite
pH (4336)
pH (4337)
Go to SETTINGS>Other Settings to select hardness and nitrate units.
Copper concentrations over 4 ppm will result in low total hardness results.
Test results that are out of range of the reagent system wil be RED.
not be accurate. Go SETTINGS>Other Settings to turn the Ranges Enabled feature OFF.
Not intended for testing ultra-pure samples such as samples from reverse osmosis
systems.
Units allows the selection of units for the Hardness test results to be
reported as gpg or ppm for the Drinking Water market. It also allows
the selection of the Nitrate test results to be reported as ppm Nitrate
(NO
) or ppm Nitrate Nitrogen (NO
3
ppm Nitrate (NO
) the nitrite results will be reported as ppm Nitrite
3
(NO
). When results are reported as nitrate nitrogen NO
2
nitrite results will be reported as ppm Nitrite Nitrogen (NO
About... lists the Serial Number, Firmware Version, Bluetooth MAC
address, Bluetooth Version and Test Count. The Test Count shows
the number of complete tests that have been performed over the
lifetime of the meter. Tap
Ranges Enabled allows the option of having test results that are
out of the range of the reagent system displayed in red. The default
setting is on.
When Show Market Type is selected, the market type will be displayed
on the Testing Screen. The default setting is OFF. Tap
the Settings menu.
Select Disk Detection to display an error message and abort the
test when improper testing conditions, such as No Disk, No Disk
Cover, Used Disk or Meter Check Disk, are present that would result
in inaccurate or no test results. The default setting is OFF. Tap
return to the Settings menu.
Range
0–250 ppm
0.00–15.00 ppm
0.00–15.00 ppm
0.00–15.00 ppm
0.0-6.0 ppm
0–70 gpg/0-1200 ppm
0.0–6.0 ppm
0.0–6.0 ppm
0.0-6.0 ppm
0-45 ppm/0-11 ppm
0.0-2.0 ppm/0.0-0.6 ppm
6.4-10.0
4.5-8.6
-N). When results are reported as
3
to return to the Settings menu.
Display Abbreviation
Hardgpg/T HARD
NITRATE/NITRATE-N
NITRITE/NITRITE-N
11
-N) the
3
-N).
2
to return to
ALK
FCL
TCL
CCL
COPPER
FERROUS
FERRIC
T IRON
pH
pH
RED
test results may
to

Publicidad

Tabla de contenido
loading

Tabla de contenido