Installation Instructions - Stainless Steel Installation
STEP 9 CONNECT WATER SUPPLY
(cont.)
• Locate and bring tubing to the front of the cabinet.
• Turn the water on to flush debris from line. Run about
a quart of water through tubing into a bucket, then
shut off water.
Copper Tubing:
• Slip a 1/4" nut
and ferrule
(provided) over
both ends of the
copper tubing.
Insert tube into
the union fitting
on the unit and
tighten nut to
union.
• Turn on the water
to check for leaks.
SmartConnect
™
Tubing:
NOTE: The only Cafe-approved plastic tubing is
supplied in the SmartConnect
Do not use any other plastic water supply line because
the line is under pressure at all times. Other types of
plastic may crack or rupture with age and cause water
damage to your home.
• Insert the molded end of the tubing into the
refrigerator connection. Tighten the compression nut
until it is just hand tight.
• Tighten one additional turn with a wrench.
Overtightening can cause leaks!
• Turn on the water to check for leaks.
NOTE: Make sure excess tubing length does not
interfere with drawer closing or toekick installation.
STEP 10 CONNECT POWER
• Check to be sure the power cord is plugged into the
receptacle.
Electrical Outlet
• Check to make sure power to refrigerator is on by
opening refrigerator door to see if interior lights are on.
• The temperature controls are preset at 37°F for the
fresh food section and 0°F for the freezer.
• Allow 24 hours to stabilize before making adjustments.
12
Refrigerator
House
Water Supply
Water Supply
™
Refrigerator Tubing kits.
STEP 11 START ICEMAKER
WARNING
Connect to potable water supply
only. A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 psi (275-827 kilopascals).
WARNING
ELECTRIC SHOCK HAZARD
Attach tubing clamp using existing hole only. DO NOT
drill into the refrigerator.
• The icemaker will begin operation automatically.
• Be sure nothing interferes with the sweep of the
feeler arm.
• Discard the first full bucket of ice cubes.
• To turn the icemaker off, slide the switch to O (OFF).
Power
Switch
STEP 12 INSTALL TOEKICK
• Locate the supplied toekick (shipped taped to the side
of the refrigerator). Install the toekick assembly with
the 2 screws provided, adjust to the desired height
and tighten the screws.
IMPORTANT: A custom toekick can be installed to
match or complement the surrounding cabinetry but
can NOT cover the horizontal vent slots of the factory
toe kick.
Icemaker
Feeler Arm