7
COMMISSIONING
en
7.3
Additional functions
7.4
Indication for contamination during run mode
30
O P E R A T I N G I N S T R U C T I O N S | RAY10
1
1
1
Time functions
0 s 2 s
Figure 20: Time function switch
RAY10-xxxxxM: ON delay, time delay when object is detected.
RAY10-xxxxxN: OFF delay, time delay when object is detected not any longer.
The time (0 ... 2 sec.) can be selected by turning the potentiometer up against left (0
sec.) or turning up against right (2 sec.).
Light/dark switch
DO LO
Figure 21: Light / dark switch
RAY10-xxxxxP: The sensor is in light switching mode when optional light/dark potenti‐
ometer is rotated to the "LO" position. The sensor is in dark switching mode when
optional light/dark potentiometer is rotated to the "DO" position. The green power
supply LED will flash once when the mode is changed.
Table 19: Indication for contamination
no contamination:
→ continue to set up / use
sensor
2
2
3
1-2 mm
see table
a little contamination:
→ sensor will still perform;
however, for optimal per‐
formance, clean front lens,
check alignment and dam‐
age of reflector too.
5.
contamination:
→ please clean front lens
of RAY10 and reflector,
check alignment and dam‐
age of reflector too.
8022198.1BXN / 2021-05-26 | SICK
Subject to change without notice