Max. Inlet pressure
Max. Inlet pressure
Flashback arrestor
Cover
5 . 6 .
INSTALLATION AND OPERATING INSTRUCTIONS
6 .1 . GENERAL INSTRUCTIONS
•
Failure to comply fully with the instructions in this IFU may result in: injury, death, damage to property, or
equipment, and may invalidate claims that result from the misuse or malfunction of the apparatus.
•
The outlet point unit has been leak tested by the manufacturer. All gaskets supplied with the outlet point unit
must be used in the installation. After installation the complete system must be leak tested, to check for any
leaks which may have been caused in transit, or during the installation process.
•
Tighten all connections carefully. Low pressure components should be tightened to a torque of 15-20 Nm.
•
Keep all components free from oil and grease.
•
Hands, tools, work clothes, and all other material used must also be free from oil and grease before and during
installation.
•
Check that sealing faces are clean and undamaged. Do not install components with damaged sealing faces or
gaskets.
•
Connect the outlet point connections with pre-installed pipework without stressing the outlet point unit.
Stress can cause leakage, malfunction.
6 .2 . INSTALLATION INSTRUCTIONS
Prior installation, or replacement of the outlet point, the system to which it is being installed must be shut
1.
down and all pressure evacuated.
Connect the brazing connection (1) the main pipework.
2.
Fix the holder to the wall using the mounting holes (10).
3.
In case you install the outlet point first and then the pipework, fix the holder to the wall first (point 3) and then
4.
connect brazing connection to pipework (point 2).
5.
UNISET+ only: Place the cover (12) on the 4 cover holders (11) premounted to the base plate. Move the cover
down to lock it at the holders as demonstrated on the picture.
7 .
OPERATOR INSTRUCTIONS
Operating instructions must be accessible and kept close to the equipment .
Personnel using the equipment must have been trained how to operate the high pressure valve unit system .
Always follow the environmental, cleanliness and safety guidelines for working with high pressure oxygen .
The equipment should be kept free from of oil or grease . Always wash your hands prior to handling the high
pressure valve unit or the cylinder .
In the outlet point area, no smoking, naked lights, cigarettes, or storage of flammable materials is permitted .
Protect the outlet point from dust, water, and caustic/toxic environments which could be detrimental to the
product .
If the operator suspects or is aware that the product is damaged or malfunctioning, its use must be ceased
immediately, and the supplier/authorised agent must be contacted .
Check that all ventilation grills are free from obstruction and that the extraction system (when installed) is
functioning correctly .
Only persons trained in safety in the workplace and accident prevention may operate the equipment .
Personnel must also have basic safety knowledge regarding the gases that are being used .
The equipment must be examined regularly to make sure that it is working correctly and that there is no gas
leakage .
Replace all worn or damaged parts with original spare parts . Gaskets, O-rings, and sealing surfaces must be
clean and free from damage to work effectively .
DINSET
UNISET
40 bar Other gases
-
-
-
Safety Instructions
9/76
UNISET +
30 bar Oxygen
Brass-Ni-coated
Stainless steel
HF SET
EN
-
-