Cleco Tools CellClutch CLBA Manual De Instrucciones página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Problem
Tool not recognized.
Tool starts in tightening direc-
tion, but not in counterclock-
wise rotation.
Tool does not start with coun-
terclockwise rotation activated.
Tool shuts off prematurely.
Tool does not change speed.
Status/work light is disabled.
No-load speed not reached.
Expected number of test run-
downs is not achieved with one
charge of the battery.
Status light flashes, see chap-
ter 5.1 Status Indication,
page 9.
Apex Tool Group
Possible causes
Tool temperature is too high.
Battery voltage is too low.
Software is incorrect.
Connection to laptop/PC is not
available.
Tool is defective.
No speed programmed for
counterclockwise rotation.
With counterclockwise rotation,
parameter for Speed is 0 rpm.
Operator releases start trigger
before the controller stops the
tool.
The fastening time exceeds
the standard time of 10 sec-
onds.
Tool exceeds the angle set-
point.
Speed is the same in all
stages.
Disabled by parameter set-
tings.
Battery voltage is too low.
Battery is not fully charged.
High torque is needed during a
fastening sequence, e.g. for
coated fastenings.
Battery is at end of life.
Encoder is defective.
Tool temperature is too high.
Battery voltage is too low.
P2547BA | 2021-08
Measure
► Cool down the tool.
► Change battery.
► Check CellClutch laptop/PC software.
► Check USB cable.
► Check PC driver.
► Change tool.
► Program the counterclockwise rotation: In the
CellClutch PC software, set the Rotation to
Reverse in the Forward and Reverse Application
Settings and parameterize the Speed.
If Forward is selected for
Enabled Direction, the
counterclockwise rotation of the
reverse switch has no function.
► Program the speed for counterclockwise rotation:
In the CellClutch PC software, set the Speed
and Rotation in the Forward and Reverse Appli-
cation Settings.
► Make sure that the operator keeps the start trig-
ger pressed throughout the entire sequence.
► Increase the fastening time.
► Check the fastening sequence to ensure that the
torque shutoff value and/or angle setpoint are
correct. Adjust as necessary.
► Check whether the fastening joint has changed
significantly.
► Make sure that the speed in the stages is correct.
► Parameterize the work light: In the CellClutch
PC software, select Bright or Dim for Work Light.
► Parameterize the status light: In the CellClutch
PC software, select Bright or Dim for Status Light.
► Use a fully charged battery.
► Use a fully charged battery.
If a high torque is needed for a longer period, e.g. for
several turns, the number of rundowns that can be
achieved with one battery charge will be significantly
reduces.
After 800 charging cycles, the capacity is reduced to
approx. 60%.
► Use new battery.
► Press start switch. If the status light continues to
flash, send the tool to a Sales & Service Center
for repair.
► Allow the tool to cool down. The current rundown
can be terminated, but a new one cannot be
started.
► Change battery.
1
EN
13

Publicidad

Tabla de contenido
loading

Productos relacionados para Cleco Tools CellClutch CLBA

Este manual también es adecuado para:

Cellclutch clbp

Tabla de contenido