Before commissioning

After unpacking the device, check it for completeness and possible transport damage
to avoid any hazards. In case of doubt, do not use it, but contact our customer
service. The service address can be found at the end of this manual.
Your device is in a package to protect it from transport damage.
Carefully remove the device from its sales packaging.
Remove all packing parts.
Clean the unit and all accessories from packaging dust residue, as described in the chapter
"Maintenance".

Commissioning

Before connecting the power plug, check the device and especially the cable for damage. The
device may only be operated with a faultless mains cable.
Connect the power cord and switch on the unit with the on/off switch.
WARNING: Always allow the appliance to run for at least 35 minutes before switching it off
and never switch it off and on continuously. There would be a risk of compressor damage.
Leave the Comedes BTR 50 to stand for at least 3 minutes after switching off, without moving
the appliance, so that the water in the drip tray can drain completely.
The higher the humidity in a room and the higher the temperature in it, the better the
Comedes BTR 50 can dehumidify the air. Therefore, the compressor will generate heat and
thus heat the room air. This is quite normal and need not worry you.
Note: Before using the device for the first time, we recommend that you operate it for 5-10
minutes with the window open to remove any production-related residues. Any smell that may
occur is normal and disappears after a short time. This is not a malfunction of the device.
Ensure adequate ventilation.
On / Off switch:
Press the On / Off switch to switch on the appliance; the dehumidifier starts in continuous
operation and the current indoor humidity is shown on the display.
Press the On / Off switch again to turn the unit off. The compressor switches off immediately,
the fan switches off with a 1 minute delay.
In standby, "- -" is shown on the display.
Automatic operation
The device is equipped with a modern hygrostat (humidity controller) and switches off
automatically when the desired humidity is reached. The compressor switches off first and then
the fan 60 seconds later. If the humidity in the room rises again, the Comedes BTR 50 switches
on again automatically.
In automatic mode, values from 20% to 90% can be set.
The basic setting in automatic mode is a target humidity of 50%.
If the "CNT" LED does not light up, the unit is in automatic mode and the desired target
humidity can be set in 5% steps by repeatedly pressing the plus or minus key.
The switching hysteresis is 3%RH.
EN-11
www.comedes.com