WARNING
WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD.
All Models must be mounted in an enclosure with a minimum ingress protection rating of
at least IP54 and must be Class I, Zone 2 certified, and used in an environment of not more
than pollution degree 2.
The device may only be operated so that there is adequate protection against ultraviolet light.
The device must not be operated in the area influenced by charge-producing processes.
The device must be set up and installed so that it is mechanically protected.
After disconnecting connections (signal/supply cable), before the connectors are plugged in
again, the connectors must be checked for contamination and, if necessary cleaned.
5.3.2.8
Datos técnicos
Tabla 5-17
Nombre del producto
Radiofrecuencias
Frecuencia de funcionamiento Valor nominal
Datos eléctricos
Potencia de salida (entrada de la antena)
Alcance máximo
Velocidad máxima de transferencia de datos
lector ↔ transpondedor
Velocidad de transferencia
SIMATIC RF300
Manual de sistema, 02/2021, C79000-G8978-C345-09
ADVERTENCIA
Datos técnicos del lector RF350R
ANT 1
ANT 3
ANT 12
ANT 18
ANT 30
Lectura
Escritura
SIMATIC RF350R
13,56 MHz
≃ 0,4 W
1)
140 mm
50 mm
16 mm
35 mm
55 mm
Transpondedo‐
res
RF300
≤ 8000
bytes/s
≤ 8000
bytes/s
19,2; 57,6; 115,2 kBd
5.3 SIMATIC RF340R/RF350R
6GT2801-4BA10
6GT2801-4BA10-0AX2
Transpondedo‐
Transpondedo‐
res
res ISO
ISO
(MDS E)
(MDS D)
≤ 3300
≤ 3400
bytes/s
bytes/s
≤ 1700
≤ 800
bytes/s
bytes/s
Lector
171