Electrical Connections
12-24VDC Models – Connect the power source positive (+) lead to the red wire and connect the power
•
source negative (-) lead to the black wire.
120-240VAC 50/60Hz Models – Connect the line (L or L1) power source lead to the black wire and
•
connect the neutral (N or L2) power source lead to the white wire. Connect ground to the green/yellow wire
if required.
Changing the Light Pattern with Power Select™: FB2LEDX is factory set to 60FPM. Change to 120FPM or
steady by cycling the power.
1. Enter programming mode by turning the input power on and off three times at a rate of 1 cycle per second.
This timing cycle must be adhered to or the programming request will be ignored.
2. To switch to the next light pattern, cycle the power from off to on. Repeat this step to move to the next
pattern.
3. To exit programming mode and set the pattern in memory, let the light operate for at least 15 seconds and
turn power off for more than 5 seconds.
Testing/Operating: After installation, test the system to verify each signal operates and establish a program
for periodic testing of the device. Provide copy of these instructions to all operating personnel.
Ordering Replacement Parts and Accessories: If your unit requires a part not listed below, it must be
replaced or repaired.
Description
PCBA, 24VDC, Amber, Red, Green
PCBA, 24VDC, Clear, Blue
PCBA, 120-240VAC, Amber, Red, Green
PCBA, 120-240VAC, Clear, Blue
Wire Guard
Wall Mounting Bracket Assembly
Technical Assistance:
Repair Service: A return for repair authorization is required. Contact your Authorized Distributor or Federal
Signal Customer Support at +1-708-534-4756 or iordersup@fedsig.com. Defective products under warranty
will be repaired or replaced at Federal Signal's discretion. Lamp failures excluded.
Product Returns: A return authorization is required from Federal Signal prior to returning the product. Contact
your Authorized Distributor for more information or to request a product return.
2645 Federal Signal Drive, University Park, Illinois 60484
Additional translations available at www.fedsig.com
Traducciones adicionales disponibles en www.fedsig.com
Customer Support 1-800-344-4634+1-708-534-4756, iordersup@fedsig.com
Technical Support 1-800-755-7621+1-708-587-3587, signalsupport@fedsig.com
www.fedsig.com
To avoid electrical shock, do not connect wires when circuits are energized.
Part Number
K20000401A
K20000401A-01
K20000426A
K20000426A-01
FB2G
LHWB
Contact our technical support team at +1-708-587-3587 or signalsupport@fedsig.com.
FB2G
PCBA
25500561A Rev. A2 0720
LHWB
Printed in U.S.A.