Connecting Can Bus (Control Current) Cables - Vetus BOW PRO Serie BOWB285 Manual De Instalación

Ocultar thumbs Ver también para BOW PRO Serie BOWB285:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
Make sure that the voltage stated on the motor type plate is
identical to the boat's power supply voltage.
To allow the bow thruster or stern thruster to be distinguished
on the CAN bus, these must be configured appropriately.
Bow thruster
The configuration as supplied is for application as a bow thruster.
Stern thruster
Configure a stern thruster by pressing the "PRESS FOR BOW
OR STERN" button on the underside of the cover.
vetus® Installation manual BOW PRO Series Thruster: BOWB285 - BOWB300 - BOWB320
n
ote
n
ote
5.6

Connecting CAN bus (control current) cables

See diagrams from page
107
if multiple panels have to be connect-
ed.
The CAN bus power supply must always be connected to
12 Volt (≥10 V, ≤16 V). Use the E-Drive MPE1KB key switch as
power supply.
As required by international standards, all neutral (negative)
conductors of the DC system must be connected to one
central point. This prevents not only dangerous situations and
corrosion problems, but also error messages in the CAN bus
system.
ENGLISH
n
ote
c
aution
020814.01
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bowb300Bowb320Bowpro285Bowpro320Bowpro300