Connecting the supply cable to the mains
Install a standardized plug corresponding to the load
indicated on the data plate. When connecting the
cable directly to the mains, install an omnipolar
circuit-breaker with a minimum contact opening of 3
mm between the appliance and the mains. The
omipolar circuit breaker should be sized according to
the load and should comply with current regulations
(the earth wire should not be interrupted by circuit
breaker).
The supply cable should be positioned so that it does
not reach a temperature of more than 50 with
respect to the room temperature, anywhere along its
length.
Before making the connection, check that:
 the electrical safety of this appliance can only be
guaranteed if the cooker is correctly and
efficiently earthed, ways ensure that the
earthing is efficient; if you have any doubts call in
a qualified technician to check the system. The
manufacturer declines all responsibility for
damage resulting from a system which has not
been earthed.
 Before plugging the appliance into the mains,
check that the specifications indicated on the
date plate (on the appliance and/or packaging)
correspond to those of the electrical mains
system of your home.
 Check that the electrical capacity of the system
and sockets will support the maximum power of
the appliance, as indicated on the data plate. If
you have any doubts, call in a qualified
technician.
 If the socket and appliance plug are not
compatible, have the socket replaced with a suitable
model by a qualified technician. The latter, in
particular, will also have to ensure that the cross
section of the socket cables are suitable for the
power absorbed by the appliance. The use of
adapters, multiple sockets and/or extensions, is not
recommended. If their use cannot be avoided,
remember to use only single or multiple adapters
and extensions which comply with current safety
regulations. In these cases, never exceed the
maximum current capacity indicated on the single
adapter or extension and the maximum power
indicated on the multiple adapter. The plug and
socket must be easily accessible.
Connection with rigid pipe (cooper or steel)
Connection to the gas system must be made in such a
way as not tot cause any stress of any kind on the
appliance. There is an adjustable L-shaped pipe
fitting on the supply ramp to the appliance, whose
watertightness is ensured by a seal. Should you need
to turn the pipe fitting, you must in all cases replace
the seal (provided with the appliance). The gas
supply pipe fitting is a threaded 1/2 gas cylindrical
male attachment.
Connecting a flexible jointless stainless steel pipe to a
threaded attachment
The gas supply pipe fitting is a threaded 1/2 gas
cylindrical male attachment. Only use pipe and seals
that comply with the current National Norms. These
pipes must be installed so that their length is never
any longer than 2000mm when fully extended. Once
the connection has been made, ensure that the
flexible metal pipe does not touch any moving parts
and is not crushed.
Checking that the connection is tight
When installation is complete, check the pipe fittings
for leaks using a soapy solution. Never use a flame.
Adapting to different types of gas
In order to adapt the oven to a different type of gas
with respect to the gas for which it was
manufactured (indicated on the label), follow these
simple steps:
a) Replacing the oven burner nozzle
Open the oven door fully
Pull out the sliding oven bottom
Unscrew the burner fastening screws
Remove screw "V" and then the oven burner;
Unscrew the oven burner nozzle using the
special socket spanner for the nozzles, or a 7mm
socket spanner, and replace it with a nozzle
suited to the new type of gas (see Table 1)