6.8. Equipotential Bonding:
In addition to the equipment-grounding conductor discussed earlier that runs with the circuit conductor's and is
connected to the equipment grounding terminal, all washers or appliances in the vicinity must be permanently
interconnected with a grounded connector.
The external connection points marked on the back of the washer serve for this purpose. See illustration below.
The cross-sectional area of the conductor must be at least electrically equivalent to the cross-sectional area of
the copper conductor used to power the washer.
1.
Protective grounding structure
2.
External protective conductor connection point
3.
Protective interconnecting conductor
4.
Grounding identification