Troubleshooting - K2 Pumps PPV10001SPK Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

Read and understand safety and operating instructions in this manual before doing any work on pump!
Only qualified personnel should electrically test the pump motor! FAILURE TO PUMP; REDUCED CAPACITY OR
DISCHARGE PRESSURE.
Problem
The pump does not pump
water.
The pump is experiencing
electrical issues.
The pump is experiencing
mechanical troubles and
noise.
14
Possible Cause
The pump is not priming.
There are leaks in the suction
piping.
The suction inlet is above water
level.
The vertical distance of the
pump is too high to water lever.
The pump is clogged.
The impeller and diffuser are
worn.
The pump is incorrect for this
installation.
The voltage is incorrect.
There are issues with the piping.
The pump is improperly
mounted.
Corrective Action
1. Pump must be primed. Make sure that pump
body and basket body are full of water. See
priming instructions.
2. Make sure there are no leaks in suction
piping.
3. Make sure suction inlet is well below the
water level to prevent pump from sucking air.
4. Pump is designed to prime at a vertical
distance of 10 ft. or less. Verify suction lift is 10
ft or less. Lower pump closer (vertically) to
water source.
1. Make sure suction trap is not clogged; if it is,
then clean trap and strainer.
2. Make sure the impeller is not clogged
3. Impeller and diffuser may be worn. If so,
order replacement parts. For more information
call customer service.
4. The pump may be trying to push too high a
column of water. If so, a "higher head" pump is
needed.
1. Pump may be running too slowly; check
voltage at motor terminals and at meter while
pump is running. If low, see wiring instructions
or consult power company. Check for loose
connections
2. Pump may be too hot.
A. Check line voltage; if less than 90% or more
than 110% of rated voltage consult a licensed
electrician.
B. Increase ventilation.
C. Reduce ambient temperature.
D. Tighten any loose connections.
1. If suction and discharge piping are not
adequately supported, pump assembly will be
strained. See "Installation".
2. Do not mount the pump on a wooden
platform! Securely mount on a concrete
platform for quietest performance before
working on pump or motor.
For Professional Technical Support call 1-844-242-2475

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ppv15001spk

Tabla de contenido