Mounting In A Control Panel; Mounting Instructions - Kübler CODIX 541 Instrucciones De Puesta En Servicio

Contadores indicadores electrónicos
Ocultar thumbs Ver también para CODIX 541:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

The device is not suitable for use in hazardous
areas and for areas excluded in EN 61010 Part
1. If the device is used to monitor machines or
processes in which, in the event of a failure of
the device or an error made by the operator,
there might be the risk of damaging the ma-
chine or causing an accident to the operators,
it is your responsibility to take the appropriate
safety measures.
The device has been designed for indoor op-
eration. It may nevertheless be used outdoors,
provided the technical data is adhered to. In
this case, take care to provide suitable UV
protection.

2.2 Mounting in a control panel

Mount the device away from heat
!
sources and avoid direct contact
with corrosive liquids, hot steam
or similar.
CAUTION
Provide a free space of 10 mm all
around the device for its ventilation.
The device should be mounted so
that the terminals are out of the
reach of the operator and cannot be
touched by him. When mounting the
device, consider the fact that only
the front side is classified as acces-
sible for the operator.

Mounting instructions

1. Remove the mounting clip from the device.
2. Insert the device from the front into the
panel cut-out, ensuring the front-panel gas-
ket is correctly seated.
3. Slide the fixing clip from the rear onto the
housing, until the spring clamps are under
tension and the upper and lower latching
lugs have snapped into place.
Note: In case of proper installation, IP65 can
be reached on the front side.
Page 2
2.3 Electrical Installation
The device must be disconnected
!
from any power supply prior to any
installation or maintenance work.
Make sure that no more voltages
DANGER
LIABLE TO CAUSE AN ELECTRO-
CUTION are present.
AC-powered devices must only
be connected to the low-voltage
network via a switch or circuit
breaker installed close to the device
and marked as their disconnecting
device.
Installation or maintenance work
must only be carried out by qualified
personnel and in compliance with
the applicable national and interna-
tional standards.
Take care to separate all extra-low
voltages entering or exiting the
device from hazardous electrical
conductors by means of a double or
reinforced insulation (SELV circuits).
The device must be protected
!
externally for its proper operation.
Information about the prescribed
fuses can be found in the technical
DANGER
information.
It must also be made sure that,
even in case of a malfunction,
the values stated in the technical
data are under no circumstances
exceeded
• The cables and their insulation must be
designed for the planned temperature and
voltage ranges. Regarding the type of the
cables, adhere to the applicable standards of
the country and of the plant. The cross sec-
tions allowed for the screw terminals can be
found in the technical data.
• Before starting the device, check the cables
for proper wiring and tightening. The screws
of unused screw terminals must be screwed
to the stop, so that they cannot loosen and
get lost.
www.kuebler.com

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Codix 542Codix 543Codix 544

Tabla de contenido