2. Inputs
INP A
Dynamic count input.
INP B
Dynamic count input.
SET/RESET
Dynamic SET/RESET input. Linked in parallel
to the red SET/RESET key. Resets the counter
to the predefined setting value.
3. Optocoupler output
Active if count value < 0. Simple preset count-
er can be realized, when using subtract mode.
4. Programming routine
The programmable parameters of the device
are described below, in the order in which they
can be set. The device is fully programmed
after one pass of the routine.
The first values stated correspond
to the factory settings.
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U B
4.2 Switching on the 30 Hz filter (INP A, INP B)
30 Hz filter off (f
30 Hz filter on
www.kuebler.com
(optional)
)
max
4.3 Input mode
Count input and count direc-
tion input
INP A: Count input
INP B: Count direction input
Differential input
IINP A: count input adding
INP B: count input sub-
Totalising
INP A: count input adding
INP B: count input adding
Quadrature input
INP A: count input 0°
INP B: count input 90°
Quadrature input with pulse
doubling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
will be counted
Quadrature input with pulse
quadrupling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
and INP B will be counted.
4.4 Multiplying factor
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to
4 decimal places. „0" is not
accepted!
tracting
Page 5