4.

Initial commissioning

4.1

Commissioning

i
The scope of commissioning depends on the
product variant ordered.
1. Remove the packaging from all components
supplied.
2. Fit mounting for BEA 070 (fig. 4, item 2) to the
trolley.
!
The mounting must always be attached firmly to
the trolley to prevent the suspended BEA 070 from
dropping.
2
1
Fig. 4:
Fix the mounting bracket
1 BEA 070
2 Mounting
3. Attach BEA 070 (fig. 4, item 1) in the mounting
and, if wished for, plug the USB connection cable
on the BEA 070 and USB port to the front of the PC
(fig. 1, item 9).
4. Connect power supply cable to the BEA 070 and to
the socket strip (fig. 1, item 10).
5. Attach the BEA 040 on the side below the KTS
module and BEA 030. Fasten either by means of
the hook-and-loop strips provided or by means
of mounting bracket 1 681 332 332 (optional
accessory).
6. Connect sensors, exhaust gas sampling probe and
adapter cables to their intended slots on BEA 040,
BEA 055, BEA 070, and KTS module (see the
relevant operating instructions).
!
The voltage supply for KTS 560 or KTS 590 must be
connected by means of the barrel connector with
label "⌀2.5 KTS560" on the trolley. The voltage
supply for other KTS modules must be connect by
means of the barrel connect with label "⌀2.1".
Robert Bosch GmbH
Initial commissioning | FSA 740 | 25 |
7. Remove transportation safeguards from laser
printer in accordance with the enclosed
instructions. Place laser printer (fig. 1, item 7) in
the trolley and connect it. Power supply cable and
USB connecting cable are provided in the trolley,
ready to be connected.
"
FSA 740 is ready for operation.
4.2

Prior to initial switch-on

The voltage supply is provided by the mains voltage
system. FSA 740 is set to 220 VAC $ 240 VAC,
50/60 Hz. Note the relevant information on the label
on the front of the EPS FSA 740.
!
Before commissioning, ensure that the voltage
in the mains voltage system matches the voltage
setting of FSA 740. If FSA 740 is operated
outdoors, we recommend using a voltage source
that is protected by a ground fault interrupter
(GFI).
i
The laser printer is designed for a voltage supply of
220 VAC $ 240 VAC, 50/60 Hz.
4.3

Language selection in Windows

After switching on for the first time, select the
language of the Windows operating system from the
menu and follow the on-screen instructions (see "PC"
operating instructions).
The language cannot be changed later any more. If
this proves necessary, please contact your Bosch
authorized dealer.
4.4
Commissioning of KTS 560, BEA 040,
BEA 055, BEA 070
The enclosed operating instructions and the Online
Help from DDC describe the commissioning of the
KTS module. Commissioning of BEA 040, BEA 055
and BEA 070 is described in the enclosed operating
instructions and in the Online Help from CDC.
Commissioning of the laser printer is described in the
enclosed operating instructions.