Step 1: Before cleaning, always
disconnect the pump from the power
source and remove the inlet screen.
Step 2: Remove the impeller housing
to expose the impeller assembly.
Remove the impeller assembly by
gently pulling on the impeller blades.
The impeller is held in place by a
magnet. NOTE: This pump uses a very
strong magnet. To protect your fingers
from potential injury, use caution when
removing or inserting the impeller.
Step 3: Use a soft cloth or
brush and warm water to
clean the impeller and the
inside of the impeller and rotor
housing.
Step 4: Reassemble all
pump parts, place the pump
inside the Pump barrier bag
and place in water before
reconnecting to the power
source.
TROUBLESHOOTING
IF THE PUMP FAILS TO OPERATE:
• Check to make sure the power cord is plugged in, the
pump is getting power.
• Check the pump outlet and any tubing, nozzles, spitters
etc. for kinks or obstructions.
• Remove the inlet screen and/or pump cover, and impeller
housing to expose the impeller. Turn the impeller to ensure
that it is not broken or jammed. Also check to make sure
that the ceramic shaft or bearings are not broken.
IF THE PERFORMANCE OF THE PUMP IS NOT
SATISFACTORY OR THE PUMP DOES NOT FLOW EVENLY:
• Check to make sure the pump is completely submerged in
water.
• Check to make sure the impeller and the housing are
clean.
• Check to make sure the Pump barrier bag is clean.
For more information on product maintenance and
maintenance videos, visit www.totalpond.com