EN
3
SPECIFICATIONS
Heat output set in the factory
(1)
Heat capacity set in the factory
Fuel
(2)
NOx emissions
Control and command equipment
Flame sensor
Ignition transformer
Fuel oil pump
Pump coil
Electric motor
Capacitor
Power supply
Power input (during operation) (+/- 5W)
Electrical protection
Sound pressure level
Storage room temperature
Operating temperature
Reference conditions: Room temperature 20 °C – Barometric pressure 1013 mbar – Altitude 0 m.a.s.l..
(1)
m
CAUTION
The burner is suitable for use with diesel containing a biofuel blend of up to 10%. A minimum requirement for biofuel
(2)
blends (up to 10%) is that they be obtained with diesel in accordance with the applicable standards and in conformity to the
local regional regulations.
If the biofuel contains an organic blend above 10%, contact the manufacturer.
kcal/h
kg/h
(1)
watt
dB(A)
SIME FUEL 25 EV
SIME FUEL 35 EV
(vers. std)
(vers. std)
kW
27
34,8
23,220
29,928
2,25
2,9
Diesel, viscosity 1.6–6 mm
[in accordance with Regulation (EC) No. 813/2013 and the EN 267:2020 stan-
dard Class 4] < 120 mg/kWh
[in accordance with Regulation (EC) No. 813/2013 and the EN 267:2020
Fida 2P 26 kV pp-35 mA rms
Inco 4 μF, TEKNO 45T (T = top series)
1 / 230 / 50 Ph / V / Hz
W
183
IP
°C
°C
SIME FUEL
SIME FUEL 25 EV
SIME FUEL 35 EV
(vers. HE)
27
23,220
2,25
/s a (Hi=12.01 kWh/kg)
2
< 120 mg/kWh
standard Class 4]
EBR - M14 R 15-15
EBR FTEB (Black)
Suntec ALV 35A
871 T80
EBR 90 W, 2800 rpm
90
181
IP40
65
-20 ... +70
-10 ... +60
(vers. HE)
34,8
29,928
2,9
43