Safety and operating instructions
Data plate
Machine type
A.
B.
Maximum hydraulic pressure
C.
Serial number
The warning symbol together with the book
D.
symbol means that the user must read the
safety and operating instructions before the
machine is used for the first time.
E.
The CE symbol means that the machine is
EC-approved. See the EC Declaration of
Conformity which is delivered with the
machine for more information.
Noise level label
The label indicates the guaranteed noise level
corresponding to EC-directive 2000/14/EC. See
"Technical data" for accurate noise level.
Labels on the accumulator
Read through the overhaul instructions carefully
before servicing or charging.
12
The accumulator must only be charged with
Nitrogen.
NOTICE
Only certified personnel are allowed to
work with the accumulator.
Transport
WARNING
Falling breaker can cause
injuries
Place the hydraulic breaker in a safe position
►
where it can not fall over and cause damage.
Carefully check that the carrier is stable enough
when transporting or performing maintenance or
other kind of work on the hydraulic breaker. The
hydraulic breaker is delivered in a box. To lift out the
hydraulic breaker in a safe way, use the lifting eye.
Installation
Before installing the hydraulic breaker on the carrier
or operating it, read the operation manual and safety
instructions provided by the carrier manufacturer.
Follow all instructions.
The carrier must have the appropriate hydraulic
system for operation of the breaker.
If the carrier is too large for the hydraulic breaker it
may lead to broken insertion tools and increased
wear. See "Technical data" for choosing suitable
carrier.
The safety equipment in the hydraulic system must
be checked for quality (CE mark, etc.), suitability and
functionability by a professional or authorised
supervisor before use.
9800 1050 90 | Original instructions
RX 2, 3, 4, 6, 8