Assembly - Chicago Pneumatic RX 2 Instrucciones De Operación Y Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 70
Safety and operating instructions

Assembly

WARNING
Falling breaker can cause
injuries
Place the breaker in a safe position where it can
not fall over and cause damage.
Preparation
1. Place the breaker in a position where it is easy
and safe to mount the adapter plate.
Mounting the adapter plate
2. Place a locking washer pair on each screw.
3. Tighten the screws with an spanner.
14
4. Always use NORDLOCK™ washers under bolt
and nut (NORDLOCK™ is a registered trademark
of Nord-Lock AB).
5.
Adapter plate
RX 2
RX 3
RX 4
RX 6
RX 8
Connecting the breaker to the carrier
6. Place the breaker in a safe way at installation.
7. Carefully lower the stick of the boom into the
adapter.
WARNING
Moving parts can crush
and cut
Never check bores or passages with hands or
fingers.
An assistant should direct the movement of the
dipper arm until the bores in the dipper arm are
flush with those in the adapter.
Agree with the assistant on clear hand signals
for use during the mounting procedure.
8. Insert the pin and lock
9. Lift up the hydraulic breaker using the boom.
10. Extend the bucket cylinder until the bore in the
toggle is flush with those in the adapter. Insert
toggle pin and lock.
9800 1050 90 | Original instructions
RX 2, 3, 4, 6, 8
Tightening torque
200 Nm
200 Nm
390 Nm
390 Nm
390 Nm

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rx 3Rx 4Rx 6Rx 8

Tabla de contenido