If the mains cable is damaged or severed during
work, do not touch the cable and remove the
mains plug immediately. Never use the appliance
when the power cord is damaged.
▸
Wear suitable ear protectors!
▸
Suitable safety gloves and non-slip shoes are
recommended.
▸
When connected to the compressed air supply,
the compressed air system automatically tra-
verses the machine to the start position!
▸
The device can only be used as a complete unit,
comprising driving tool and column.
▸
Prior to screwing, check whether the screwing
location is free from obstacles. When placing
screws, cables, pipes or containers may be inad-
vertently damaged.
▸
The device may only be used on a horizontal,
non-skid substrate.
▸
Only insert the plug with the device switched off
and after use remove the plug.
▸
Always lead the cable away from the front of the
machine.
▸
The use of non-approved accessories can cause
accidents.
Noise /vibration information
The noise level may exceed 80 dB(A)
during work.
Risk of severe injuries and acoustic
Â
trauma.
Wear suitable ear defenders.
¾
The measured values conform to DIN EN 60745-1
und EN ISO 11201:1995.
▸
A-valued emitted noise level at the workstation:
L
= 88 dB(A)
pA, 1s
▸
A-weighted emitted sound power level:
L
= 101 dB(A)
WA, 1s
The weighted mean square value of the hand arm
acceleration in frequency is 3.0 m/s².
(This value increases temporarily during tightening.)
14
Safety Instructions
WARNING!
▸
Protect the electronic device from rain or mois-
ture. If water enters the electronic device, there is
an increased risk of electric shock.
▸
When working outside use only extension cords
which are suitable for outdoor use. Using a suit-
able cord minimizes the risk of electric shock.
▸
The mains voltage must conform with the voltage
specified on the name plate.
▸
Always hold the nailer firmly in both hands when
working with it and ensure you work on stable
ground.
▸
Hold the power tool by the insulated gripping
surfaces, when performing an operation where
the cutting accessory may contact hidden wiring
or its own cord. Contact with a live cable can
make metallic parts of the device live and may
lead to an electric shock.
Technical Data
VSG 80
Rated power consumption 1700 W
No-load / load speed
1st gear
2nd gear
Screw Ø
Screw length
Compressed air connec-
tion
Working pressure
Max. inlet pressure
Dimensions (L x W x H)
Weight
Protection class
IP code
Art. 0702 080 0
290 - 770 rpm
640- 1650 rpm
5.5 - 8.0 mm
38 - 100 mm
1/4"
6.3 (90) bar (psi)
8.0 (120) bar (psi)
45 x 41 x 99 cm
22 kg
/II
IP 20