Basic description of unit control and settings

Switching on
Main screen information
After turning the unit on, you
The next screen shows
will see information about the
current airfl ow, fi lter clog-
manufacturer of the unit on
ging and battery level. You
your display.
can also see the current
headtop and fi lter setting.
How to get to the main menu
Press the
and
button at the same
time and hold them for 2 seconds. The
main menu will appear.
How to navigate in the menu and
change settings:
• Press the
button and jump to the
next menu item, or hold the
for 2 sec to jump to the previous item.
• Press the
button and change the
settings of the item.
• Press both buttons for 2 seconds to
save the settings and leave the menu
(not pressing anything for 5 sec does
the same).
Unit headtop setting:
Go to the unit menu (
and
and repeat pressing
until the required
headtop standard appears.
9.

Storage

All parts of the CleanAIR® system must be stored at temperatures between -10 °C and 55 °C, with relative air humidity be-
tween 20 and 95% Rh.
Batteries will self-discharge during storage. Therefore, it is recommended to charge the battery for 1 hour at least every 3
months. The optimal battery charge level for longer storage is between 50 - 70% of capacity. After longer storage time it is
necessary to repeat 3 charging cycles to reach battery's full capacity.

10. Warranty

The warranty ensures that you will receive a replacement if a product has any manufacturing or material defects that appear
within 12 months of the date of purchase. The same period for batteries is 6 months from the date of purchase. The warran-
ty claim must be reported to the sales department/retailer. At the same time, proof of purchase must be submitted (i.e. an
invoice or certifi cate of delivery). The warranty can only be acknowledged if no interventions into
unit and charger have been made. The warranty does not cover defects caused by the late replacement of fi lters, or
by using a fi lter which was damaged by cleaning or being blown through.
The manufacturer strongly recommends to perform periodical inspections in CleanAIR® authorized service center.
Inspections should be done according the local law and at least once in every two years.
8
Airfl ow adjustment
Rotating display
You can adjust airfl ow by
By briefl y pressing down on
simple pressing the
or
both buttons you can rotate
button on the side of the unit.
the display clockwise by 90
The available airfl ow setting
degrees.
depends on the headtop and
fi lter setting.
How to change the fi lter setting:
Go to the unit menu (
and
for 2 sec) and press
once to get to the next item; repeat pressing
until the required fi lter standard appears.
Available
How to change the language
languages
To change the language, go to
button
the menu (
and
English
time for 2 seconds) and then to
French
the language item* (press the
German
button four times); press the
Czech
button to select the required
Norwegian
language. By not pressing any-
Dutch
thing for 6 seconds your set-
Italian
tings will be confi rmed.
Spanish
Russian
for 2 sec)
* In order to ease fi nding "lan-
Hebrew
guage item" is highlighted by
Polish
symbols ">" and "<".
the powered respiratory
11.

Technical data

Technical specifi cations - CleanAIR® MedicAER®
Airfl ow
Display
Weight of unit, including battery
Unit noise
Battery lifespan
One charging cycle
Belt - waist size
Operating temperature
Operating humidity
Certifi cation
The unit conforms with IP65 - IP68 (Ingress Protection against liquids and solid particles):
IP64: When the unit is powered on (no additional requirements)
IP65: When the unit is on (attached spark arrestor and pre-fi lter holder set - 50 01 12)
IP68: When unit is off (with inlets and outlets closed by decontamination plugs - 51 00 46)
Notifi ed body for testing CE:
at the same
Declaration of Conformity is available at: https://www.clean-air.cz/doc/MedicAER.pdf
12. List of spare parts
Order code:
51 M0 00FC
51 M0 10
51 M0 20
52 00 44.1
51 00 41
51 00 42
51 00 30EUR
51 00 30UK
71 00 60
71 00 60L
71 00 86
71 00 86L
70 00 62F
70 00 62C
71 00 92
52 00 90
51 00 46
120 - 235 l/min
TFT display
960 g
55 to 61 dB
Max. 500 recharging cycles
less than 3 hours
up to 1,500 mm
0 to 60 °C
20 to 95% Rh
EN 12941/A2 TH2/TH3; EN 12942/A2 TM2/TM3
Occupations Safety Research Institute
Jeruzalémská 1283/9, 110 00 Praha 1
Autorizovaná osoba 235
Notifi ed body 1024
Description:
CleanAIR® MedicAER® (with charger, comfort belt, standard battery, air hose, set of P R SL fi lters,
fl ow indicator and plastic transport case)
Standard battery for MedicAER® (Li-Ion 14,4 V / 2,6 Ah)
Heavy Duty battery for MedicAER® (Li-Ion 14,4 V / 5,2 Ah)
Comfort harness
Decontaminable belt
Decontaminable harness
Charger Li-Ion 14,4 V - EURO plug
Charger Li-Ion 14,4 V - UK plug
Light fl exi hose QuickLOCK
Light fl exi hose QuickLOCK extended
Rubber hose QuickLOCK
Rubber hose QuickLOCK extended
Hose cover fl ameproof
Hose cover chemical resistant
Comfort padded belt
Flow indicator CA40x1/7"
Set of decontamination plugs
9