During the transport and maintenance of the
-
appliance the extraction opening is to be
closed with the connection socket.
WARNING
Safety equipment for preventing haz-
ards must be serviced and maintained
regularly. This means that the manufac-
turer's staff or persons trained by the
manufacturer must check the equipment
for proper functioning at least once a
year, i.e. check for leaks, filter damage,
functioning of the controlling elements,
etc.
ATTENTION
Risk of damage! Do not use detergents
containing silicone to clean.
No outside help is required for carrying out
-
basic maintenance and cleaning.
The appliance surface and the inside of the
-
container should be cleaned regularly using a
damp cloth.
DANGER
Risk due to dust hazardous to health. Al-
ways use disposal clothing and P2 or
higher breath-safe masks while carrying
out maintenance tasks (such as changing
filters).
Exchanging the flat pleated filter
 Open filter door.
 Take out the flat folded filter.
 Dispose off the used flat-folded filter in a dust-
 Remove the dirt that has accumulated on the
pure air side.
 Insert new flat-folded filter.
 Close the filter door, it must lock into place.
Replacing the fleece filter bag/dust
ing.
bag
Exchange the fleece filter bag
Illustration
 Insert the new fleece filter bag.
Replace the disposal bag
Illustration
 Release and remove the suction head.
 Attach the new disposal bag.
 Insert and lock the suction head.
Replace membrane filter
Illustration
 Release and remove the suction head.
 Pull the new membrane filter over the contain-
er edge.
 Insert and lock the suction head.
Cleaning the electrodes
 Clean the electrodes with a brush.