EN
b. As a stationary machine on the subframe. In
this case the machine must be secured to the
subframe with 4 bolts and the subframe
anchored to the floor or to a floor plate with
dimensions of at least 1 square meter.
Guide fence insert
Fig. H, I, J
For safety reasons, this machine is equipped with
a guide fence insert
to be used when using the machine for sawing
straight cross-cuts.
•
For sawing straight cross-cuts, the guide
fence insert must remain mounted on the
machine (fig. H).
•
For sawing mitre cuts, the guide fence insert
must be removed from the machine as shown
(fig. H).
•
For sawing bevel cuts, the guide fence insert
must be removed from the machine as shown
(fig. I+J).
Mounting and removing the saw blade
Fig. A+B
Do not use the machine without the
guard.
Mounting
•
Pull out the locking knob (3) and raise the saw
head (12).
•
Loosen the bracket (29) by removing the
screw (30).
•
Raise the guard (6).
•
Keep the spindle lock button (7) pressed and
loosen the bolt (19) using the spanner (20).
•
Remove the flanges (21 & 22).
•
If necessary, clean the flanges (21 & 22).
•
Mount the flange (22).
•
Mount the saw blade (5). Make sure that the
arrow on the saw blade points in the same
direction as the arrow on the saw head.
•
Mount the flange (21).
•
Keep the spindle lock button (7) pressed and
tighten the bolt (19) using the spanner (20).
•
Lower the guard (6).
•
Mount the bracket (29) by tightening the screw
(30).
Removing
•
Pull out the locking knob (3) and raise the saw
head (12).
•
Loosen the bracket (29) by removing the
10
screw (30).
•
Raise the guard (6).
•
Keep the spindle lock button (7) pressed and
loosen the bolt (19) using the spanner (20).
•
Remove the flange (21).
•
Remove the saw blade (5).
•
Mount the flange (21).
•
Keep the spindle lock button (7) pressed and
tighten the bolt (19) using the spanner (20).
•
Lower the guard (6).
•
Mount the bracket (29) by tightening the screw
(30).
Setting the mitre angle
Fig. C
•
The mitre angle is left/right variable between
0° and 45°. The mitre angle can be read from
the scale (9).
Do not set the mitre angle during use.
•
Slacken the locking knob (8).
•
Turn the saw table (13) to the required
position.
•
Tighten the locking knob (8).
Setting up the double sawing angle / mitring
Fig. D
•
Adjust the first angle as described for
adjusting the saw angle (above).
•
Turn the knob (10) anticlockwise and then set
the angle desired (you can read this off on the
back of the machine. Then tighten the knob
(10) again by turning it clockwise.
Changing the carbon brushes
Fig. A
•
Make sure that the plug is not in the socket!
•
Unscrew the covers (16) with a flat bladed
screwdriver. Remove the carbon brushes with
the same type of brushes. Screw the covers
(16) tight again.
Note: Always replace both carbon brushes at the
same time. Never use a mixture of old and new
brushes.
Mounting the dust bag
Fig. F
Press in the clamp of the dust bag (27) and slide it
onto the opening on the back of the machine. The
dust bag stays in place when you release the clamp.
Ferm