6 Putting into operation
NOTICE
• The extraction system must be at least 1.0 m away from the wall.
• Select a location that enables a short and straight extraction hose feed and prevents it from entering the employee's
space of movement.
• Protect the components from rain and direct sunlight.
• Only use the device in dry, clean and well-ventilated rooms.
 Fig. 2 Functional description on page EN-10
1 Position the extraction system appropriately and lock the castors (1).
6.2 Attaching the welding torch's extraction hose
NOTICE
• Depending on the version, either 1 to 2 or 1 to 4 external fume extraction torches (1) can be connected.
1
2
1
Fume extraction torch
2
Extraction system
Fig. 3
Attaching the welding torch's extraction hose
1 Connect the extraction hose (4) to the air intake fittings (3) on the extraction system (2).
6.3 Attaching the compressed air hose
1 Screw in the compressed air connector, including the seal (included in the scope of delivery).
2 Attach the compressed air hose to the compressed air connector (5).
EN - 12
3
4
3
Air intake fittings
4
Extraction hose
5
BAL.0732.0 • 2019-09-18
xFUME VAC PRO
5
Compressed air connector